    Climate, buildings and occupant expectations: a comfort-based model for the design and operation of office buildings in hot humid conditions

    12749_Kishnani Nirmal 2002.pdf (14.50Mb)
    Access Status
    Open access
    Authors
    Kishnani, Nirmal
    Date
    2002
    Type
    Thesis
    Award
    PhD
    
    Metadata
    Show full item record
    School
    School of Architecture, Construction and Planning
    URI
    http://hdl.handle.net/20.500.11937/2325
    Collection
    • Curtin Theses
    Abstract

    Office buildings in hot humid Singapore appear to be designed for stable and uniform indoor conditions. It is proposed in this thesis that this is unnecessary, as occupant comfort expectations do not warrant it and energy is wasted as a result. A comfort-based approach to design is advocated, as a means of balancing user needs with the objective of energy conservation.This issue of how perception of comfort is linked with indoor stability emerged from the question, 'why do office buildings, despite Bioclimatic prescriptions for hot humid conditions, continue to be predominantly climate rejecting and active-run?' The literature was found to be polarised by arguments for architectural solutions that are climatically responsive and present lower energy costs, and those for engineered solutions that deliver greater, more consistent comfort, albeit through reliance on electro-mechanical systems.It is argued that comprehending the gaps in the literature, and between theory and application, requires a better understanding of occupant comfort. This would be an inside-out view of comfort and climate, predicated on how the occupant is affected by the building and the cognitive nature of comfort itself.Relying on a sample of office buildings, the thesis set out to establish the following:Prevalence of the climate-based approach, specifically Yeang's Bioclimatic ModelPrevalence of uniformity and stability of the indoor environmentOccupant perception of indoor comfort, both thermal and visual, particularly with regard to variability of ambient conditionsOccupant perception of various operational modes: passive, mixed and activeThese goals were addressed through observations of form, envelope and layout, occupant surveys and the monitoring of buildings in passive and active modes.It was found that the Bioclimatic approach is non-existent in the context of the Singapore office building. In the case of two Bioclimatic buildings in Malaysia, the Model is not consistently applied. This disparity appears partly due to conflicting priorities, in particular style, cost and client pressures, and partly due to assumptions about occupant comfort.The Singapore office building was found to be predominantly active-run, operating within a narrow bandwidth of temperatures across most spaces. Occupant perception of variability outside the primary workplace, however, is one of acceptance, even preference. It was found through analysis of user feedback that the office building, on the basis of comfort expectations, could be divided into three activity zones: Work, Support and Transit.This 3-tiered structure was subsequently tested through a large-scale, longitudinal survey carried out across three spaces, each representing an activity zone, within a single building. The survey was accompanied by adjustments to the building's temperature settings to test the limits of acceptance in each zone. Findings from this exercise support the notion of a three-zoned office building, in which thermal conditions for each zone could be varied without affecting comfort. Energy figures that were monitored before and after the resetting showed drops of 7.1 % in chiller consumption and 2.9% in overall consumption.These findings led to a comfort-based, tri-modal proposal for office buildings in hot humid conditions, defined as the Psychoclimatic Model for its basis in comfort expectations and the interaction between climate, building and the occupant.The implications of the thesis outcome on regulatory control in Singapore and thermal comfort theory are discussed. Recommendations are made for future research into other building types and national context, plus a parametric study into the full energy-saving potential of the Psychoclimatic Model.

    Related items

    Showing items related by title, author, creator and subject.

    • Optimal price based control of HVAC systems in multizone office buildings for demand response
      Amin, Uzma ; Hossain, M. J.; Fernandez, E. (2019)
      Optimizing the scheduling of heating, ventilation, and air-conditioning (HVAC) systems in multizone buildings is a challenging task, as occupants in various zones have different thermal preferences dependent on time-varying ...
    • Engineering Solutions to Optimise the Design of Carbon-Neutral Tall Office Buildings
      Pitman, Mark; King, Andrew (2009)
      Energy efficiency differs by building use and type as well as prevailing climatic conditions. This study examines the energy efficiency of tall office buildings in a Mediterranean climate by investigating the energy balance ...
    • Energy efficient design in housing of small floor area : appropriateness in housing for the aged
      Karol, Elizabeth (2003)
      This thesis seeks to address energy efficient design in a temperate climate in typical small, medium density housing, particularly in housing for the aged. The connections between energy efficient design and small, medium ...
    Advanced search

    Browse

    Communities & CollectionsIssue DateAuthorTitleSubjectDocument TypeThis CollectionIssue DateAuthorTitleSubjectDocument Type

    My Account

    Admin

    Statistics

    Most Popular ItemsStatistics by CountryMost Popular Authors

    Follow Curtin

    • 
    • 
    • 
    • 
    • 

    CRICOS Provider Code: 00301JABN: 99 143 842 569TEQSA: PRV12158

    Copyright | Disclaimer | Privacy statement | Accessibility

    Curtin would like to pay respect to the Aboriginal and Torres Strait Islander members of our community by acknowledging the traditional owners of the land on which the Perth campus is located, the Whadjuk people of the Nyungar Nation; and on our Kalgoorlie campus, the Wongutha people of the North-Eastern Goldfields.