    Experimental study on the effect of a heated plume within vented enclosures

    160533_Tiong 2011.pdf (1.402Mb)
    Access Status
    Open access
    Authors
    Tiong, Ing Kee
    Date
    2011
    Supervisor
    Dr. Ramesh Narayanaswamy
    Type
    Thesis
    Award
    MPhil
    
    Metadata
    Show full item record
    Faculty
    Faculty of Science and Engineering, Department of Mechanical Engineering
    URI
    http://hdl.handle.net/20.500.11937/934
    Collection
    • Curtin Theses
    Abstract

    This thesis presents an experimental study on the effect of a heated plume within vented enclosures. The characteristics of a heated plume within enclosures are studied using controlled and systematic experiments, simulating the movement of heated air due to the development of fire within a room.A short enclosure (Case CS1) and a tall enclosure (Case CS2) were subjected to two heating configurations representing natural and forced convection heat transfer. The cross-sectional dimension of the enclosures, and the heating power were maintained the same for both cases in order to compare the plume effects due to the change of height. For each case, different combinations of top ventilation were also considered for the present experiments.The air temperature and pressure within the enclosure were measured with suitable thermocouples and pressure probes, specially fabricated and mounted on racks that were positioned at three locations: (i) at 100 mm above the base of the enclosure; (ii) middle of the enclosure; and (iii) at 100 mm below the ceiling of the enclosure. The ceiling temperature profile was also obtained to determine the ceiling jet impingement.The experimental results show that for both case studies – CS1 and CS2, for the same heat transfer mechanism (natural or forced convection), the hot air temperature within the enclosure is decreased due to an increase in the number and size of vents. Hot air is exhausted quicker into the ambient and the exchange rate of hot air inside the enclosure and cool air from the ambient is increased. It was found that natural convection mechanism led to a higher ceiling and air temperature distribution than forced convection. The short enclosure had a higher ceiling temperature compared to the tall enclosure. Correlations for ceiling temperature distribution for short and tall enclosures are also provided. The study has resulted in obtaining valuable conclusions for the effect of a heated plume within a vented enclosure.

    Related items

    Showing items related by title, author, creator and subject.

    • Experimental investigation of surface radiation and mixed convection heat transfer in duct flows
      Rajamohan, Ganesan (2012)
      Mixed convection heat transfer in horizontal and vertical ducts with flow through the duct plays an important role in the design and operation of several industrial equipment involving heat transfer and fluid flow phenomena. ...
    • Evaporation of a sessile binary droplet on a heated spherical particle
      Nguyen, T.; Mitra, S.; Pareek, Vishnu; Joshi, J.; Evans, G. (2018)
      © 2018 Elsevier Inc. This study investigated the evaporation behaviour of a binary droplet system (diameter: ~2.6–2.9 mm) comprising water-glycerol mixture (0–35 wt.%) in contact with a spherical particle heated in the ...
    • Heat transfer and fluid flow characteristics of synthetic jets
      Jagannatha, Deepak (2009)
      This thesis presents a fundamental research investigation that examines the thermal and fluid flow behaviour of a special pulsating fluid jet mechanism called synthetic jet. It is envisaged that this novel heat transfer ...
    Advanced search

    Browse

    Communities & CollectionsIssue DateAuthorTitleSubjectDocument TypeThis CollectionIssue DateAuthorTitleSubjectDocument Type

    My Account

    Admin

    Statistics

    Most Popular ItemsStatistics by CountryMost Popular Authors

    Follow Curtin

    • 
    • 
    • 
    • 
    • 

    CRICOS Provider Code: 00301JABN: 99 143 842 569TEQSA: PRV12158

    Copyright | Disclaimer | Privacy statement | Accessibility

    Curtin would like to pay respect to the Aboriginal and Torres Strait Islander members of our community by acknowledging the traditional owners of the land on which the Perth campus is located, the Whadjuk people of the Nyungar Nation; and on our Kalgoorlie campus, the Wongutha people of the North-Eastern Goldfields.