This phantom study was designed to compare the radiation dose in thoracic and abdomen-pelvic CT scans with and without use of tube current modulation (TCM). Effective dose (ED) and size-specific dose estimation (SSDE) were calculated with the absorbed doses measured at selective radiosensitive organs using a thermoluminescence dosimeter-100 (TLD-100). When compared to protocols without TCM, the ED and SSDE were reduced significantly with use of TCM for both the thoracic and abdomen-pelvic CT. With use of TCM, the ED was 6.50 ± 0.29 mSv for thoracic and 6.01 ± 0.20 mSv for the abdomen-pelvic CT protocols. However without use of TCM, the ED was 20.07 ± 0.24 mSv and 17.30 ± 0.41 mSv for the thoracic and abdomen-pelvic CT protocols, respectively. The corresponding SSDE was 10.18 ± 0.48 mGy and 11.96 ± 0.27 mGy for the thoracic and abdomen-pelvic CT protocols with TCM and 31.56 ± 0.43 mGy and 33.23 ± 0.05 mGy, for thoracic and abdomen-pelvic CT protocols without TCM, respectively. The highest absorbed dose was measured at the breast with 8.58 ± 0.12 mGy in the TCM protocols and 51.52 ± 14.72 mGy in the protocols without TCM during thoracic CT. In the abdomen-pelvic CT, the absorbed dose was highest at the skin with 9.30 ± 1.28 mGy and 29.99 ± 2.23 mGy in protocols with and without use of TCM, respectively. In conclusion, the TCM technique results in significant dose reduction, thus it is to be highly recommended in routine thoracic and abdomen-pelvic CT.
Related items
Showing items related by title, author, creator and subject.
-
Moorin, Rachael; Gibson, David A.J.; Forsyth, R.; Fox, R. (2015)PURPOSE: To evaluate the effect of introduction of iterative reconstruction as a mandated software upgrade on radiation dosimetry in routine clinical practice over a range of computed tomography examinations. METHODS: ...
-
Drake-Brockman, T.; Ramgolam, A.; Zhang, Guicheng; Hall, G.; von Ungern-Sternberg, B. (2017)Background: Perioperative respiratory adverse events (PRAE) are the most common critical incidents in paediatric anaesthesia and occur more often in infants. Use of laryngeal mask airways (LMAs) is associated with reduced ...
-
Beales, Darren (2009)Aberrant motor control strategies have been identified in chronic pelvic girdle pain (PGP) subjects. It has been proposed that aberrant motor control strategies could provide a mechanism for ongoing pain and disability ...