Show simple item record

dc.contributor.authorVerrelli, D.
dc.contributor.authorAlbijanic, Boris
dc.contributor.editorJuan Yianatos
dc.contributor.editorAlex Doll
dc.contributor.editorCesar Gomez
dc.contributor.editorRomke
dc.date.accessioned2017-01-30T11:23:57Z
dc.date.available2017-01-30T11:23:57Z
dc.date.created2015-05-22T08:32:26Z
dc.date.issued2014
dc.identifier.citationVerrelli, D. and Albijanic, B. 2014. Measuring the induction time for particle-bubble attachment in flotation, in Juan Yianatos, Alex Doll, Cesar Gomez and Romke (ed), XXVII International Mineral Processing Congress -IMPC 2014, Oct 20 2014, pp. 1-11. Santiago, Chile: Gecamin Digital Publications.
dc.identifier.urihttp://hdl.handle.net/20.500.11937/11293
dc.description.abstract

Froth flotation is an exceedingly complex physicochemical process. The convenience of distilling much of the complexity of the bubble–particle interactions into a single parameter has led to the continuing popularity of the classical ‘induction time’ to quantify the threshold for bubble–particle attachment to occur. Despite this popularity and the simplicity of the concept, there is no single universal method of evaluating the induction period. In this paper, we begin with a critical review of the available techniques for estimating the induction period. These are: back-calculation from experimental (micro)flotation tests; pushing a particle toward a stationary bubble (or vice versa) using an atomic force microscope (AFM); pushing a bubble toward a stationary bed of particles in the ‘Induction Timer’; pushing a bubble toward a stationary solid surface using the ‘integrated thin film drainage apparatus’ (ITFDA); and dropping particles onto a submerged stationary bubble using the ‘Milli-Timer’ device. Each one of these methods has advantages and disadvantages, and the best choice depends on the application. In the experimental section, we present quantitative comparison of the induction periods estimated using two different techniques, namely the Induction Timer and the Milli-Timer. The same particles were tested in each device, under the same conditions. It was found that by tuning the operation of the particle pick-up device, similar estimates of induction period could be obtained to the estimates made by direct observation with the Milli-Timer. In the former device a bubble is driven toward a particle bed at a controlled rate, whereas in the latter a particle’s motion is governed by the hydrodynamics. The potential to match these presents an intriguing prospect for better understanding the bubble–particle interaction, and the possibility to ‘calibrate’ the simpler Induction Timer against direct observations.

dc.publisherGecamin Digital Publications
dc.titleMeasuring the induction time for particle-bubble attachment in flotation
dc.typeConference Paper
dcterms.source.startPage1
dcterms.source.endPage11
dcterms.source.titleProceedings of the XXVII International Mineral Processing Congress – IMPC 2014
dcterms.source.seriesProceedings of the XXVII International Mineral Processing Congress – IMPC 2014
dcterms.source.isbn978-956-9393-19-8
dcterms.source.conferenceXXVII International Mineral Processing Congress -IMPC 2014
dcterms.source.conference-start-dateOct 20 2014
dcterms.source.conferencelocationSantiago, Chile
dcterms.source.placeChile
curtin.departmentDept of Mining Eng & Metallurgical Eng
curtin.accessStatusFulltext not available


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record