    Performance evaluation of data transmission in a single and double bus network within the utility substation based on IEC 61850

    Access Status
    Fulltext not available
    Authors
    Kumar, S.
    Das, N.
    Muigai, J.
    Islam, Syed
    Date
    2014
    Type
    Conference Paper
    
    Metadata
    Show full item record
    Citation
    Kumar, S. and Das, N. and Muigai, J. and Islam, S. 2014. Performance evaluation of data transmission in a single and double bus network within the utility substation based on IEC 61850: IEEE Computer Society.
    Source Title
    IEEE Power and Energy Society General Meeting
    DOI
    10.1109/PESGM.2014.6939273
    ISSN
    1944-9925
    School
    Department of Electrical and Computer Engineering
    URI
    http://hdl.handle.net/20.500.11937/11912
    Collection
    • Curtin Research Publications
    Abstract

    © 2014 IEEE. Communication between intelligent electronic devices (IED's) is an important feature of a utility substation automation system based on IEC 61850. Time critical information related to fault and overcurrent, under frequency messages for substation automation system (SAS) and the use of IED's from multiple vendors, has opened up issues related to a reliable protection system within the high voltage substation. Early detection of the delay in data transmission over a Generic Object Oriented Substation Event (GOOSE) network is an important step towards identification of problems associated with the dynamic protection system. It is observed that non critical messages adds up the queuing time and delays in the delivery of the messages which could be an issue in the reliable operation of a protection system. In this paper an Optimized Network Engineering Tool (OPNET) model is created, tested and analysed for a single and double bus configuration in detail for the delay encountered in data transfer within a typical zone substation. In order to understand the delay in transmission of packets, a 132/22kV zone substation model is analysed and results are discussed based on GOOSE communication in an IEC 61850 environment. Further, the delay in communication is compared and analysed between a single and double bus system of a 132/22kV substation to determine the best alternative technique available from protection point of view in a SAS network.

    Related items

    Showing items related by title, author, creator and subject.

    • Modelling and analysis of IEC 61850 for end-to-end delay characteristics with various packet sizes in modern power substation systems
      Wong, T.; Das, Narottam (2014)
      Substation is an important part of electricity generation, transmission and distribution system, where voltage is stepped up and down or vice versa. The substation serves as a centre point of all kind of connection between ...
    • Performance evaluation of two interconnected high voltage utility substations using PRP topology based on IEC 62439-3
      Kumar, S.; Das, Narottam; Islam, Syed (2018)
      © 2017 IEEE. In a modern power system network having multiple interconnected High Voltage (HV) substations, communication amongst Intelligent Electronic Devices (IED) becomes an important feature in an automation system. ...
    • Performance analysis of substation automation systems architecture based on IEC 61850
      Kumar, S.; Das, Narottam; Islam, Syed (2014)
      © 2014 ACPE. Digital Communications amongst multi-vendor intelligent electronic devices (IED's) is an important feature of a substation automation system (SAS). Measuring the propagation delays and assessing the ...
    Advanced search

    Browse

    Communities & CollectionsIssue DateAuthorTitleSubjectDocument TypeThis CollectionIssue DateAuthorTitleSubjectDocument Type

    My Account

    Admin

    Statistics

    Most Popular ItemsStatistics by CountryMost Popular Authors

    Follow Curtin

    • 
    • 
    • 
    • 
    • 

    CRICOS Provider Code: 00301JABN: 99 143 842 569TEQSA: PRV12158

    Copyright | Disclaimer | Privacy statement | Accessibility

    Curtin would like to pay respect to the Aboriginal and Torres Strait Islander members of our community by acknowledging the traditional owners of the land on which the Perth campus is located, the Whadjuk people of the Nyungar Nation; and on our Kalgoorlie campus, the Wongutha people of the North-Eastern Goldfields.