Show simple item record

dc.contributor.authorShannon, R.
dc.contributor.authorOslowski, S.
dc.contributor.authorDai, S.
dc.contributor.authorBailes, M.
dc.contributor.authorHobbs, G.
dc.contributor.authorManchester, R.
dc.contributor.authorvan Straten, W.
dc.contributor.authorRaithel, C.
dc.contributor.authorRavi, V.
dc.contributor.authorToomey, L.
dc.contributor.authorBhat, Ramesh
dc.contributor.authorBurke-Spolaor, S.
dc.contributor.authorColes, W.
dc.contributor.authorKeith, M.
dc.contributor.authorKerr, M.
dc.contributor.authorLevin, Y.
dc.contributor.authorSarkissian, J.
dc.contributor.authorWang, J.
dc.contributor.authorWen, L.
dc.contributor.authorZhu, X.
dc.date.accessioned2017-01-30T11:36:22Z
dc.date.available2017-01-30T11:36:22Z
dc.date.created2014-09-10T20:00:19Z
dc.date.issued2014
dc.identifier.citationShannon, R. and Oslowski, S. and Dai, S. and Bailes, M. and Hobbs, G. and Manchester, R. and van Straten, W. et al. 2014. Limitations in timing precision due to single-pulse shape variability in millisecond pulsars. Monthly Notices of the Royal Astronomical Society. 443 (2): pp. 1463-1481.
dc.identifier.urihttp://hdl.handle.net/20.500.11937/13332
dc.identifier.doi10.1093/mnras/stu1213
dc.description.abstract

High-sensitivity radio-frequency observations of millisecond pulsars usually show stochastic, broad-band, pulse-shape variations intrinsic to the pulsar emission process. These variations induce jitter noise in pulsar timing observations; understanding the properties of this noise is of particular importance for the effort to detect gravitational waves with pulsar timing arrays. We assess the short-term profile and timing stability of 22 millisecond pulsars that are part of the Parkes Pulsar Timing Array sample by examining intraobservation arrival time variability and single-pulse phenomenology. In 7 of the 22 pulsars, in the band centred at approximately 1400 MHz, we find that the brightest observations are limited by intrinsic jitter. We find consistent results, either detections or upper limits, for jitter noise in other frequency bands. PSR J1909-3744 shows the lowest levels of jitter noise, which we estimate to contribute ~10 ns root mean square error to the arrival times for hour-duration observations. Larger levels of jitter noise are found in pulsars with wider pulses and distributions of pulse intensities. The jitter noise in PSR J0437-4715 decorrelates over a bandwidth of ~2 GHz. We show that the uncertainties associated with timing pulsar models can be improved by including physically motivated jitter uncertainties. Pulse-shape variations will limit the timing precision at future, more sensitive, telescopes; it is imperative to account for this noise when designing instrumentation and timing campaigns for these facilities.

dc.publisherOxford University Press
dc.subjectstars: neutron
dc.subjectpulsars: general
dc.subjectmethods: data analysis
dc.titleLimitations in timing precision due to single-pulse shape variability in millisecond pulsars
dc.typeJournal Article
dcterms.source.volume443
dcterms.source.startPage1463
dcterms.source.endPage1481
dcterms.source.issn0035-8711
dcterms.source.titleMonthly Notices of the Royal Astronomical Society
curtin.note

This article has been accepted for publication in Monthly Notices of the Royal Astronomical Society. ©: 2014 The Authors, Published by Oxford University Press on behalf of the Royal Astronomical Society. All rights reserved.

curtin.departmentCurtin Institute of Radio Astronomy
curtin.accessStatusOpen access


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record