Translations equations to compare ActiGraph GT3X and Actical accelerometers activity counts
Citation
Source Title
Additional URLs
ISSN
Faculty
School
Remarks
© The Author(s). 2012 Published in BMC Medical Research Methodology.
Collection
Abstract
Background: This study aimed to develop a translation equation to enable comparison between Actical and ActiGraph GT3X accelerometer counts recorded minute by minute. Methods: Five males and five females of variable height, weight, body mass index and age participated in this investigation. Participants simultaneously wore an Actical and an ActiGraph accelerometer for two days. Conversion algorithms and R2 were calculated day by day for each subject between the omnidirectional Actical and three different ActiGraph (three-dimensional) outputs: 1) vertical direction, 2) combined vector, and 3) a custom vector. Three conversion algorithms suitable for minute/minute conversions were then calculated from the full data set. Results: The vertical ActiGraph activity counts demonstrated the closest relationship with the Actical, with consistent moderate to strong conversions using the algorithm: y = 0.905x, in the day by day data (R2 range: 0.514 to 0.989 and average: 0.822) and full data set (R2 = 0.865). Conclusions: The Actical is most sensitive to accelerations in the vertical direction, and does not closely correlate with three-dimensional ActiGraph output. Minute by minute conversions between the Actical and ActiGraphvertical component can be confidently performed between data sets and might allow further synthesis of information between studies.
Related items
Showing items related by title, author, creator and subject.
-
Straker, Leon ; Campbell, Amity (2012)Background: This study aimed to develop a translation equation to enable comparison between Actical and ActiGraph GT3X accelerometer counts recorded minute by minute. Methods: Five males and five females of variable height, ...
-
Mitchell, L.; Ziviani, J.; Boyd, Roslyn (2015)Copyright © 2014 by the American College of Sports Medicine. Introduction: This study aimed to establish the variability in the measurement of habitual physical activity using the ActiGraph® GT3X+ accelerometer in children ...
-
Clanchy, K.; Tweedy, S.; Boyd, Roslyn; Trost, S. (2011)To evaluate the validity of the ActiGraph accelerometer for the measurement of physical activity intensity in children and adolescents with cerebral palsy (CP) using oxygen uptake (VO 2) as the criterion measure. Thirty ...