dc.description.abstract

Locomotives in heavy haul and high speed passenger operations represent several megawatts of electrical load. Single phase power collected by a pantograph is typically rectified by multiple PWM converters. The converter switching instants are phased to ensure ripple current cancellation, assuming that the converter loads are balanced. Partial failures may result in unbalanced operation with reduced cancellation. The resulting harmonics may adversely impact the signalling systems and/or result in over voltage effects due to resonance in the overhead supply system. This paper examines a 4 MW locomotive with three rectifier modules and a device switching frequency of 900 Hz. This results in a5400 Hz ripple frequency in the mains current. Ideal balanced operation of converters is compared to anunbalanced operation case. Unbalanced cases include rectifier failures, inverter failures and changes in the relative balance of power delivered to each axle of the locomotive. This paper will consider what may be the most frequently occurring case; that of loss of load in one traction motor due to wheel slip. Current ripple cancellation is partially lost in this case and lower frequency current components can be produced. An active filter is proposed as a means to retain an acceptable harmonic performance for the locomotive.

dc.publisherEngineers Australia
dc.relation.urihttp://search.informit.com.au/browseJournalTitle;res=IELENG;issn=1448-837X
dc.subjectActive power filter
dc.subjectPWM Locomotive
dc.subjectline current spectrum
dc.titleAn Active Power Filter Method to Improve the Line Current Spectrum of PWM Locomotive Rectifiers with Load Unbalance
dc.typeJournal Article
dcterms.source.volume3
dcterms.source.number2
dcterms.source.startPage129
dcterms.source.endPage136
dcterms.source.issn1448-837X
dcterms.source.titleAustralian Journal of Electrical & Electronics Engineering
curtin.accessStatusFulltext not available
curtin.facultyDepartment of Electrical and Computer Engineering
curtin.facultySchool of Engineering
curtin.facultyFaculty of Science and Engineering


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record