Show simple item record

dc.contributor.authorLin, Jianyu
dc.date.accessioned2017-01-30T12:07:24Z
dc.date.available2017-01-30T12:07:24Z
dc.date.created2014-02-20T20:00:40Z
dc.date.issued2013
dc.identifier.citationLin, Jianyu. 2013. On Artifact-free Projection Overlaps in Multi-pinhole Tomographic Imaging. IEEE Transactions on Medical Imaging. 32 (12): pp. 2215-2229.
dc.identifier.urihttp://hdl.handle.net/20.500.11937/18345
dc.identifier.doi10.1109/TMI.2013.2277588
dc.description.abstract

In multi-pinhole SPECT, overlapping the projections from different pinholes has been used to increase sensitivity. However, the prevailing view is that the overall quality of the reconstructed image is not improved by the overlaps in the projections. It is often stated in literatures that overlaps introduce ambiguous information, which can lead to nonuniqueness of solution for the inverse problem, and thus artifacts are introduced in the reconstructed image. On the other hand, contrary to the prevailing view, a recent study on slit-slat collimators shows that artifacts can be removed with the “help” of an extra complete nonoverlapped projection data set. In this paper, two types of artifact-free projection overlaps are defined in general, and the criteria for designing artifact-free multi-pinhole systems with overlaps are proposed. It is shown that once the criteria are satisfied, the solution of the inverse problem is unique, and thus no artifact is expected in the reconstructed image. Via extensive simulation study, various artifact-free overlapping multi-pinhole systems are designed and validated. It is shown that overlaps in the artifact-free systems can improve contrast-to-noise ratio (CNR). With a proper design, the CNR for an artifact-free overlapping system can be significantly higher than that for the corresponding nonoverlapping system. The improved image quality is also confirmed with noisy reconstructions.

dc.publisherInstitute of Electrical and Electronics Engineers
dc.subjectArtifacts in the reconstructed image
dc.subjectmultiple pinhole single photon emission computed tomography (SPECT)
dc.subjectquality of the reconstructed image
dc.subjectprojection overlaps (multiplexing)
dc.titleOn Artifact-free Projection Overlaps in Multi-pinhole Tomographic Imaging
dc.typeJournal Article
dcterms.source.volume32
dcterms.source.startPage2215
dcterms.source.endPage2229
dcterms.source.issn02780062
dcterms.source.titleIEEE Transactions on Medical Imaging
curtin.department
curtin.accessStatusFulltext not available


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record