Influence of flow-interruption on filter performance during the filtration of liquid aerosols by fibrous filters
Access Status
Authors
Date
2012Type
Metadata
Show full item recordCitation
Source Title
ISSN
Remarks
NOTICE: this is the author’s version of a work that was accepted for publication in Separation and Purification Technology. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. Changes may have been made to this work since it was submitted for publication. A definitive version was subsequently published in Separation and Purification Technology, Volume 90, April 2012, Pages 53-63, http://dx.doi.org/10.1016/j.seppur.2012.02.009,
Collection
Abstract
This study investigated the influence of flow interruptions on the filtration performance of two different multi-layered fibrous filters during liquid aerosol filtration. It was found that both types of filters experienced a significant secondary loading stage, though they had reached a steady state for continuous flow. The filters showed distinctive increases in pressure drop and filter saturation until a second equilibrium state was reached. This second equilibrium state was attributed to a rearrangement of liquid in the filter during the breaks, clogging previously free passages. The ratio of shear and capillary forces was found to determine whether these passages were able to be “cleaned” once airflow was recommenced. Based on these findings, the airflow required to clean fully saturated filters was investigated and a phenomenological model developed to describe this behaviour. Furthermore, it was found that filters could be cleaned and reused, whereby they would return to one of the previous steady states (continuous or discontinuous flow). The experiments conducted in this work represent a more realistic test for oil-mist (or coalescing) filters than typical laboratory testing. Furthermore, it is hoped that they will help to bridge the gap between laboratory and field test results.
Related items
Showing items related by title, author, creator and subject.
-
Tseng, Chien H. (1999)The design of envelope-constrained (EC) filters is considered for the time-domain synthesis of filters for signal processing problems. The objective is to achieve minimal noise enhancement where the shape of the filter ...
-
Mead-Hunter, Ryan; Braddock, Roger; Kampa, D; Merkel, Nini; Kasper, Gerhard; Mullins, Benjamin (2012)This work details the results of a study into the relationship between pressure drop and liquid saturation in mist (or coalescing) filters. Liquid saturation (clogging) in mist filters is of critical importance as it is ...
-
Abishek, Sridhar; King, Andrew; Schuler, J.; Kasper, G.; Schmid, H.; Mullins, B. (2018)Pore-scale filtration simulations require high spatio-temporal resolutions and significant computational effort, hence, keeping the domain size to a minimum is desirable. Previous studies have considered domains based on ...