Separate assessment of gluteus medius and minimus: B-mode or M-mode ultrasound?
Access Status
Authors
Date
2014Type
Metadata
Show full item recordCitation
Source Title
ISSN
School
Remarks
Copyright © 2014 Informa Healthcare. Published by Informa UK.
Collection
Abstract
The hip abductors gluteus medius (Gmed) and minimus (Gmin) differ slightly in function and how they are affected by hip joint pathology. A separate assessment of Gmed and Gmin is feasible by ultrasound (US) imaging. B-mode and M-mode US can be used to measure muscle thickness. Two B- and two M-mode scans of Gmed and Gmin thickness were taken in relaxation on 16 asymptomatic volunteers, repeated within 4 days on 11 subjects. Three types of intra-rater reliability of muscle thickness measurements were examined: (1) within-session reliability comparing two scans from the same session, (2) between-days reliability comparing thickness from two scanning occasion within 4 days and (3) reliability of taking thickness measurements by re-measuring the same US scans after 1 week. Thickness measurements on B- and M-mode images provided ICC3,1 >0.96 for within-session reliability. ICC3,k >0.89 for between-days reliability and ICC3,1 >0.85 for re-reading the same scans were estimated. Minimal detectable changes >1.0 mm within-session, >2.4 mm between-days and >1.7 mm for re-reading scans indicated that small thickness changes are not detectable. The investigation suggests a slight advantage for fascia recognition in B-mode and the advantage of visual control of muscle relaxation in M-mode.
Related items
Showing items related by title, author, creator and subject.
-
Dieterich, A.; Pickard, Christine; Deshon, Louise; Strauss, Geoff; Gibson, W.; Davey, Paul; McKay, J. (2015)M-mode ultrasound imaging (US) reflects motion of connective tissue within muscles. As muscle contraction is accompanied by motion of muscle tissue, M-mode US may be used to measure non-invasively the onset of deep muscle ...
-
Dieterich, A.; Deshon, L.; Strauss, Geoff; McKay, J.; Pickard, Christine (2016)Study Design: Controlled laboratory study. Background: The hip abductor muscles are important hip joint stabilizers. Hip joint pain may alter muscle recruitment. Motion-mode (M-mode) ultrasound enables noninvasive ...
-
Dieterich, Angela; Pickard, Christine; Strauss, Geoff; Deshon, Louise; Gibson, William; McKay, Jan (2014)The clinical assessment of gluteus medius and minimus force sharing requires non-invasive measurements of individual activity levels. Do ultrasound measurements of change of muscle thickness substitute invasive electromyography ...