Show simple item record

dc.contributor.authorAgarwal, S.
dc.contributor.authorAllison, Garry
dc.contributor.authorSinger, K.
dc.date.accessioned2017-01-30T12:38:34Z
dc.date.available2017-01-30T12:38:34Z
dc.date.created2010-03-03T20:02:31Z
dc.date.issued2005
dc.identifier.citationAgarwal, Shabnam and Allison, Garry and Singer, Kevin. 2005. Reliability of the Spin-T Cervical Goniometer in Measuring Cervical Range of Motion in an Asymptomatic Indian Population. Journal of Manipulative and Physiological Therapeutics. 28 (7): pp. 487-492.
dc.identifier.urihttp://hdl.handle.net/20.500.11937/23663
dc.identifier.doi10.1016/j.jmpt.2005.07.005
dc.description.abstract

Objective. To examine the intratester reliability of the Spin-T goniometer, a cervical range of motion device, in a normal Indian population. Methods. Subjects comprised 30 healthy adults with mean age of 34 years (range, 18-65 years). The subjects were stabilized in the sitting position and the Spin-T goniometer mounted on the head of the subject. The study design was a within-subject repeated intratester reliability trial conducted for cervical range of motion in 6 directions of movement. Three measurements were taken in each direction (flexion, extension lateral flexion, and lateral rotation) per participant. Reliability coefficients, intraclass correlation coefficients, and 95% confidence interval were derived from repeated-measures analysis of variance (ANOVA). Where differences in ANOVA were detected, a paired t test was conducted and the typical error values and coefficient of variance were calculated. Results. All repeated measures showed high intraclass correlation coefficients (all >0.96, P <.01). The ANOVA detected no differences between trials for all movements except rotation. The typical error values for the rotation trials did not exceed 2.5 and the coefficient of variance did not exceed 4%, which is clinically acceptable considering the normally variable cervical range of movement. Conclusion. In this study, the Spin-T goniometer proved to be a reliable measuring instrument for cervical range of movement in an Indian population. The use of a laser pointer fixed to the instrument ensured a consistent neutral start position.

dc.publisherElsevier Inc
dc.subjectArticular
dc.subjectReproducibility of Results
dc.subjectValidity
dc.subjectCervical Vertebrae
dc.subjectRange of Motion
dc.titleReliability of the Spin-T Cervical Goniometer in Measuring Cervical Range of Motion in an Asymptomatic Indian Population
dc.typeJournal Article
dcterms.source.volume28
dcterms.source.number7
dcterms.source.startPage487
dcterms.source.endPage492
dcterms.source.issn01614754
dcterms.source.titleJournal of Manipulative and Physiological Therapeutics
curtin.note

The link to the journal’s home page is: http://www.elsevier.com/wps/find/journaldescription.cws_home/623235/description#description. Copyright © 2005 Elsevier B.V. All rights reserved

curtin.accessStatusFulltext not available
curtin.facultyFaculty of Health Sciences
curtin.facultySchool of Physiotherapy


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record