    DFIG fault ride through improvement during VSC faults

    192481_95144_Published_version.pdf (6.063Mb)
    Access Status
    Open access
    Authors
    Abdou, A.
    Abu-Siada, Ahmed
    Pota, H
    Date
    2013
    Type
    Journal Article
    
    Metadata
    Show full item record
    Citation
    Abdou, A.F. and Abu-Siada, A. and Pota, H.R. 2013. DFIG fault ride through improvement during VSC faults. Energy Science and Technology. 5 (1): pp. 17-25.
    Source Title
    Canadian Research & Development Center of Sciences and Cultures
    DOI
    10.3968/j.est.1923847920130501.772
    ISSN
    1923-8460
    URI
    http://hdl.handle.net/20.500.11937/24051
    Collection
    • Curtin Research Publications
    Abstract

    The sensitivity of the doubly fed induction generator (DFIG) to external faults has motivated researchers to investigate the impact of various grid disturbances such as voltage sag and short circuit faults on the fault ride through (FRT) capability of the DFIG. However, no attention has been given to the impact of internal faults within voltage source converters (VSCs) that interface the DFIG with the grid, on the dynamic performance of the machine. This paper investigates the impact of various VSC faults on the dynamic performance and the FRT capability of the DFIG. Faults such as fire-through and flashover within the VSC switches are considered in this paper. Moreover, faults across the DC-link capacitor are included in this study as a common problem in the VSCs. The impact of these faults when they occur within the grid side converter (GSC) and rotor side converter (RSC) are investigated. A proper STATCOM controller to mitigate the effects of these faults on the FRT is proposed. The DFIG compliance with numerous and recently released FRT grid codes under these faults with and without the STATCOM are examined and compared. Furthermore, the capability of a proposed controller to bring the voltage profile at the point of common coupling (PCC) to the nominal steady-state level under five possible VSC faults cases is examined. The proposed controller is efficient, simple, and easy to implement.

    Related items

    Showing items related by title, author, creator and subject.

    • Enhanced control of DFIG-based wind power plants to comply with the international grid codes
      Mohseni, Mansour (2011)
      A review of the latest international grid codes shows that large wind power plants are stipulated to not only ride-through various fault conditions, but also exhibit adequate active and reactive power responses during the ...
    • Application of SMES Unit to improve the performance of doubly fed induction generator based WECS
      Yunus, A. M. Shiddiq (2012)
      Due to the rising demand of energy over several decades, conventional energy resources have been continuously and drastically explored all around the world. As a result, global warming is inevitable due to the massive ...
    • Application of STATCOM to improve the LVRT of DFIG during RSC Fire-through Fault
      Abdou, A.; Abu-Siada, Ahmed; Pota, H. (2012)
      The use of doubly fed induction generators (DFIGs) in large wind energy conversion systems (WECS) has significantly increased during the last few years. The DFIG is interfaced to the AC network through a grid side voltage ...
    Advanced search

    Browse

    Communities & CollectionsIssue DateAuthorTitleSubjectDocument TypeThis CollectionIssue DateAuthorTitleSubjectDocument Type

    My Account

    Admin

    Statistics

    Most Popular ItemsStatistics by CountryMost Popular Authors

    Follow Curtin

    • 
    • 
    • 
    • 
    • 

    CRICOS Provider Code: 00301JABN: 99 143 842 569TEQSA: PRV12158

    Copyright | Disclaimer | Privacy statement | Accessibility

    Curtin would like to pay respect to the Aboriginal and Torres Strait Islander members of our community by acknowledging the traditional owners of the land on which the Perth campus is located, the Whadjuk people of the Nyungar Nation; and on our Kalgoorlie campus, the Wongutha people of the North-Eastern Goldfields.