Show simple item record

dc.contributor.authorMoorin, Rachael
dc.contributor.authorGibson, D.
dc.contributor.authorForsyth, Rene
dc.contributor.authorBulsara, M.
dc.contributor.authorHolman, C.
dc.date.accessioned2017-01-30T12:45:07Z
dc.date.available2017-01-30T12:45:07Z
dc.date.created2014-02-11T20:00:31Z
dc.date.issued2014
dc.identifier.citationMoorin, Rachael E. and Gibson, David A.J. and Forsyth, Rene K. and Bulsara, Max K. and Holman, C. D'Arcy J. 2014. Evaluating data capture methods for the establishment of diagnostic reference levels in CT scanning. European Journal of Radiology. 83 (2): pp. 329-337.
dc.identifier.urihttp://hdl.handle.net/20.500.11937/24818
dc.identifier.doi10.1016/j.ejrad.2013.11.003
dc.description.abstract

Objective: Concerns about the radiation dose associated with CT scanning have led to a call for establishment of diagnostic reference levels. Self-complete surveys have been used extensively to gather this information, however, departmental Radiological Information System's/Picture Archive Communication Systems (RIS/PACS) also hold this information. We compared dosimetry derived from survey with those using RIS/PACSs.Methods: Technical data were collected from a large metropolitan tertiary hospital in WA using both data collection methods for a range of adult CT scanning examinations. Radiation dose was calculated from both datasets and the results evaluated for several indexes of inter-rater agreement.Results: Radiation dose calculated using self-report survey data differed both systematically and proportionally from that calculated using RIS/PACS data. Differences were not consistent across CT examination type and thus not amenable to simple correction. The disparity was greater and more variable for organ dose than effective dose due to reliance of survey data on “generic” anatomical start and stop limits compared with actual data available on RIS/PACS.Conclusions: The bias observed in our study indicates that care should be taken when interpreting the results of studies measuring radiation dose using self-complete surveys. The availability of electronic databases that include information required for the evaluation and monitoring of CT radiation dose provides the opportunity to capture better quality data in a cost-effective manner. We recommend that national and local databases are established that routinely capture these data so as to facilitate the development and monitoring of radiation dose associated with CT scanning.

dc.publisherElsevier Ireland Ltd
dc.subjectRadiation Dosage
dc.subjectRadiology Information - Systems
dc.subjectCT scan
dc.subjectSurvey Methods
dc.subjectRadiation Dosimetry
dc.titleEvaluating data capture methods for the establishment of diagnostic reference levels in CT scanning
dc.typeJournal Article
dcterms.source.volume83
dcterms.source.number2
dcterms.source.startPage329
dcterms.source.endPage337
dcterms.source.issn0720-048X
dcterms.source.titleEuropean Journal of Radiology
curtin.note

NOTICE: this is the author’s version of a work that was accepted for publication in European Journal of Radiology. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. Changes may have been made to this work since it was submitted for publication. A definitive version was subsequently published in European Journal of Radiology, Vol. 83, 2014. DOI: 10.1016/j.ejrad.2013.11.003

curtin.department
curtin.accessStatusOpen access


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record