dc.contributor.authorGrygoryev, K.
dc.contributor.authorHerzog, G.
dc.contributor.authorJackson, N.
dc.contributor.authorStrutwolf, J.
dc.contributor.authorArrigan, Damien
dc.contributor.authorMcDermott, K.
dc.contributor.authorGalvin, P.
dc.date.accessioned2017-01-30T12:51:01Z
dc.date.available2017-01-30T12:51:01Z
dc.date.created2014-08-26T20:00:25Z
dc.date.issued2014
dc.identifier.citationGrygoryev, K. and Herzog, G. and Jackson, N. and Strutwolf, J. and Arrigan, D. and McDermott, K. and Galvin, P. 2014. Reversible Integration of Microfluidic Devices with Microelectrode Arrays for Neurobiological Applications. BioNanoScience. 4 (3): pp. 263-275.
dc.identifier.urihttp://hdl.handle.net/20.500.11937/25941
dc.identifier.doi10.1007/s12668-014-0137-6
dc.description.abstract

The majority of current state-of-the-art microfluidic devices are fabricated via replica molding of the fluidic channels into PDMS elastomer and then permanently bonding it to a Pyrex surface using plasma oxidation. This method presents a number of problems associated with the bond strengths, versatility, applicability to alternative substrates, and practicality. Thus, the aim of this study was to investigate a more practical method of integrating microfluidics which is superior in terms of bond strengths, reversible, and applicable to a larger variety of substrates, including microfabricated devices. To achieve the above aims, a modular microfluidic system, capable of reversible microfluidic device integration, simultaneous surface patterning and multichannel fluidic perfusion, was built. To demonstrate the system’s potential, the ability to control the distribution of A549 cells inside a microfluidic channel was tested. Then, the system was integrated with a chemically patterned microelectrode array, and used it to culture primary, rat embryo spinal cord neurons in a dynamic fluidic environment. The results of this study showed that this system has the potential to be a cost effective and importantly, a practical means of integrating microfluidics. The system’s robustness and the ability to withstand extensive manual handling have the additional benefit of reducing the workload. It also has the potential to be easily integrated with alternative substrates such as stainless steel or gold without extensive chemical modifications. The results of this study are of significant relevance to research involving neurobiological applications, where primary cell cultures on microelectrode arrays require this type of flexible integrated solution.

dc.publisherSpringer
dc.subjectSurface patterning
dc.subjectReversible intergration
dc.subjectNeuronal culture
dc.subjectMicroelectrode arrays
dc.subjectMicrofluidic perfusion
dc.titleReversible Integration of Microfluidic Devices with Microelectrode Arrays for Neurobiological Applications
dc.typeJournal Article
dcterms.source.volume4
dcterms.source.startPage263
dcterms.source.endPage275
dcterms.source.issn2191-1630
dcterms.source.titleBioNanoScience
curtin.note

NOTICE: This is the author’s version of a work in which changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. Changes may have been made to this work since it was submitted for publication.

curtin.note

The final publication is available at Springer via http://doi.org/10.1007/s12668-014-0137-6

curtin.departmentDepartment of Applied Chemistry
curtin.accessStatusOpen access