Show simple item record

dc.contributor.authorVallelonga, Paul
dc.contributor.authorVan de Velde, Katja
dc.contributor.authorCandelone, Jean
dc.contributor.authorLy, Chi
dc.contributor.authorRosman, Kevin
dc.contributor.authorBoutron, C.
dc.date.accessioned2017-01-30T12:52:13Z
dc.date.available2017-01-30T12:52:13Z
dc.date.created2009-03-05T00:57:09Z
dc.date.issued2002
dc.identifier.citationVallelonga, Paul and Van de Velde, Katja and Candelone, Jean and Ly, Chi and Rosman, Kevin and Boutron, C. 2002. Recent advances in measurement of Pb isotopes in polar ice and snow at sub-picogram per gram concentrations using thermal ionisation mass spectrometry. Analytica Chimica Acta. 453 (1): pp. 1-12.
dc.identifier.urihttp://hdl.handle.net/20.500.11937/26200
dc.identifier.doi10.1016/S0003-2670(01)01490-8
dc.description.abstract

Techniques for Pb measurements have reached the stage where Antarctic ice with sub-picogram per gram concentrations can be reliably analysed for isotopic composition. Here, particular attention has been given to measuring the quantity of Pb added during the decontamination and sample storage stages of the sample preparation process because of their impact on accuracy at low concentrations. These stages, including the use of a stainless steel chisel for the decontamination, contributed 5.2 pg to the total sample analysed, amounting to a concentration increase of 13 fg g−1, which is significantly less than expected. Consequently, the corrections to the isotopic ratios and concentration were also smaller. Other contributions to the blank, such as Pb fallout onto critical working areas in the HEPA-filtered air laboratories, were also relatively small as was the amount of Pb leached from preconditioned perfluoroalkoxy (PFA) beakers during sample processing. The ion source contributed typically 89±19 fg to the blank. Although this was relatively large, its influence depended upon the amount of Pb available for analysis and it had the greatest impact when small volumes of samples with a very low concentration were analysed. A 15 months investigation of the leaching characteristics of Pb from a low-density polyethylene (LDPE) sample storage bottle showed 11 fg cm−2 per day was released immediately following the initial 2 months cleaning process, but this decreased to immeasurable values after a further 3 months of cleaning.

dc.publisherElsevier BV
dc.titleRecent advances in measurement of Pb isotopes in polar ice and snow at sub-picogram per gram concentrations using thermal ionisation mass spectrometry
dc.typeJournal Article
dcterms.source.volume453
dcterms.source.number1
dcterms.source.startPage1
dcterms.source.endPage12
dcterms.source.issn00032670
dcterms.source.titleAnalytica Chimica Acta
curtin.note

The link to the journal’s home page is: http://www.elsevier.com/wps/find/journaldescription.cws_home/502681/description#description

curtin.note

Copyright © 2002 Elsevier Ltd. All rights reserved

curtin.departmentDepartment of Imaging and Applied Physics
curtin.accessStatusFulltext not available
curtin.facultyDepartment of Medical Imaging and Applied Physics
curtin.facultySchool of Science
curtin.facultyFaculty of Science and Engineering


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record