dc.date.issued2010
dc.identifier.citationChiew, S.P. and Mei, C.C. and Lau, H.H. 2010. Use of thin-gauge galvanized C-purlin sections in long-span roof truss construction, in Chung, K.F. (ed), Third International Symposium on Cold-Formed Metal Structures, Jul 26 2010, pp. 47-68. Hong Kong: The Institute of Cold-formed Metal Structures.
dc.identifier.urihttp://hdl.handle.net/20.500.11937/26914
dc.description.abstract

Cold-formed thin-gauge galvanized steel lipped C-sections are widely used as secondary structural elements such as purlins and side rails in building construction because of its low weight and ease of handling and erection. However, these sections are frequently misconceived as having low member stiffness and poor clear spanning ability, and hence, perceived as limited in terms of alternative applications and uses. This paper examines alternative applications of such sections and an innovative example of how such sections can be used to form the long-span primary roof trusses for a church building is described in details. The structural roof layout consists of 35 numbers of main primary trusses spaced at 1.2m centres with a long clear span of 25m. One of the issues that are often raised with regards to this form of thin-gauge construction is the use of self-drilling screws which are often proprietary and system-specific in nature.To support such construction, it is often necessary to carry out some single and double lap shear joint tests to assess the shear capacity of the proprietary selfdrilling screws and to verify its design values against code calculations. In this connection, this paper reports on the direct shear tests which are conducted on a particular type of self-drilling screws. In addition, the paper also describes a full-scale proof load test which is carried out on another long-span roof truss as part of the developmental work to convince the Building Authority on the acceptance of such construction. The test objectives, methods, observations and analysis of the load test are discussed in details and the results show convincingly that such ultra-light cold-formed thin-gauge steel roof trusses can be used without any problem.

dc.publisherThe Institute of Cold-formed Metal Structures
dc.subjectlong-span
dc.subjectCold-formed
dc.subjectproof load test
dc.subjectroof truss
dc.subjectthin-gauge
dc.subjectself-drilling screw
dc.subjectlap shear joint
dc.titleUse of thin-gauge galvanized C-purlin sections in long-span roof truss construction
dc.typeConference Paper
dcterms.source.startPage47
dcterms.source.endPage68
dcterms.source.titleProceeding of the 3rd International Symposium on Cold-formed Metal Structures
dcterms.source.seriesProceeding of the 3rd International Symposium on Cold-formed Metal Structures
dcterms.source.isbn9789623676984
dcterms.source.conferenceThird International Symposium on Cold-Formed Metal Structures
dcterms.source.conference-start-dateJul 26 2010
dcterms.source.conferencelocationHong Kong
dcterms.source.placeHong Kong
curtin.departmentCurtin Sarawak - Faculty Office
curtin.accessStatusFulltext not available


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record