Show simple item record

dc.contributor.authorHickey, A.
dc.contributor.authorNewham, J.
dc.contributor.authorSlawinska, M.
dc.contributor.authorKwasnicka, Dominika
dc.contributor.authorMcDonald, S.
dc.contributor.authorDel Din, S.
dc.contributor.authorSniehotta, F.
dc.contributor.authorDavis, P.
dc.contributor.authorGodfrey, A.
dc.date.accessioned2017-01-30T12:56:31Z
dc.date.available2017-01-30T12:56:31Z
dc.date.created2016-04-10T19:30:21Z
dc.date.issued2016
dc.identifier.citationHickey, A. and Newham, J. and Slawinska, M. and Kwasnicka, D. and McDonald, S. and Del Din, S. and Sniehotta, F. et al. 2016. Estimating cut points: A simple method for new wearables. Maturitas. 83: pp. 78-82.
dc.identifier.urihttp://hdl.handle.net/20.500.11937/27036
dc.identifier.doi10.1016/j.maturitas.2015.10.003
dc.description.abstract

Wearable technology is readily available for continuous assessment due to a growing number of commercial devices with increased data capture capabilities. However, many commercial devices fail to support suitable parameters (cut points) derived from the literature to help quantify physical activity (PA) due to differences in manufacturing. A simple metric to estimate cut points for new wearables is needed to aid data analysis. Objective: The purpose of this pilot study was to investigate a simple methodology to determine cut points based on ratios between sedentary behaviour (SB) and PA intensities for a new wrist worn device (PRO-Diary™) by comparing its output to a validated and well characterised ‘gold standard’ (ActiGraph™). Study design: Twelve participants completed a semi-structured (four-phase) treadmill protocol encompassing SB and three PA intensity levels (light, moderate, vigorous). The outputs of the devices were compared accounting for relative intensity. Results: Count ratios (6.31, 7.68, 4.63, 3.96) were calculated to successfully determine cut-points for the new wrist worn wearable technology during SB (0–426) as well as light (427–803), moderate (804–2085) and vigorous (≥2086) activities, respectively. Conclusion: Our findings should be utilised as a primary reference for investigations seeking to use new (wrist worn) wearable technology similar to that used here (i.e., PRO-Diary™) for the purposes of quantifying SB and PA intensities. The utility of count ratios may be useful in comparing devices or SB/PA values estimated across different studies. However, a more robust examination is required for different devices, attachment locations and on larger/diverse cohorts.

dc.publisherElsevier Ireland Ltd
dc.titleEstimating cut points: A simple method for new wearables
dc.typeJournal Article
dcterms.source.volume83
dcterms.source.startPage78
dcterms.source.endPage82
dcterms.source.issn0378-5122
dcterms.source.titleMaturitas
curtin.departmentSchool of Psychology and Speech Pathology
curtin.accessStatusOpen access


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record