Show simple item record

dc.contributor.authorLiu, Yang
dc.contributor.authorTeng, H.
dc.contributor.authorHou, H.
dc.contributor.authorYou, T.
dc.date.accessioned2017-01-30T12:57:18Z
dc.date.available2017-01-30T12:57:18Z
dc.date.created2014-01-20T20:01:16Z
dc.date.issued2009
dc.identifier.citationLiu, Yang and Teng, Hong and Hou, Haoqing and You, Tianyan. 2009. Nonenzymatic glucose sensor based on renewable electrospun Ni nanoparticle-loaded carbon nanofiber paste electrode. Biosensors and Bioelectronics. 24 (11): pp. 3329-3334.
dc.identifier.urihttp://hdl.handle.net/20.500.11937/27142
dc.identifier.doi10.1016/j.bios.2009.04.032
dc.description.abstract

A novel non enzymatic glucose sensor was developed based on the renewable Ni nanoparticle-loaded carbon nanofiber paste (NiCFP) electrode. The NiCF nano composite was prepared by combination of electro spinning technique with thermal treatment method. The scanning electron microscopy (SEM) and transmission electron microscopy (TEM) images showed that large amounts of spherical nanoparticles were well dispersed on the surface or embedded in the carbon nanofibers. And the nanoparticles were composed of Ni and NiO, as revealed by energy dispersive X-ray spectroscopy (EDX) and X-ray powder diffraction (XRD). In application to nonenzymatic glucose determination, the renewable NiCFP electrodes, which were constructed by simply mixing the electrospun nano composite with mineral oil, exhibited strong and fast amperometric response without being poisoned by chloride ions. Low detection limit of 1M with wide linear range from 2M to 2.5mM (R = 0.9997) could be obtained. The current response of the proposed glucose sensor was highly sensitive and stable, attributing to the electro catalytic performance of the firmly embedded Ni nanoparticles as well as the chemical inertness of the carbon-based electrode. The good analytical performance, low cost and straightforward preparation method made this novel electrode material promising for the development of effective glucose sensor.

dc.publisherElsevier BV
dc.subjectElectrospinning
dc.subjectNi nanoparticle-loaded carbon nanofiber
dc.subjectGlucose
dc.subjectRenewable electrode
dc.subjectNonenzymatic sensor
dc.titleNonenzymatic glucose sensor based on renewable electrospun Ni nanoparticle-loaded carbon nanofiber paste electrode
dc.typeJournal Article
dcterms.source.volume24
dcterms.source.startPage3329
dcterms.source.endPage3334
dcterms.source.issn0956-5663
dcterms.source.titleBiosensors and Bioelectronics