    Corrosion Durability and Structural Response of RC Beams Containing Supplementary Cementing Materials

    Access Status
    Fulltext not available
    Authors
    Ahmed, Shaikh
    Maalej, M.
    Paramasivam, P.
    Mihashi, H.
    Date
    2006
    Type
    Conference Paper
    
    Metadata
    Show full item record
    Citation
    Ahmed, S. and Maalej, M. and Paramasivam, P. and Mihashi, H. 2006. Corrosion Durability and Structural Response of RC Beams Containing Supplementary Cementing Materials, in Brown, T. and Danylnk, D. (ed), 1st International Structural Specialty Conference. Alberta, CANADA: Canadian Society For Civil Engineers.
    Source Title
    1st International Structural Specialty Conference
    Source Conference
    1st International Structural Specialty Conference
    ISBN
    1-894662-08-3
    Faculty
    School of Engineering
    Department of Civil Engineering
    Faculty of Science and Engineering
    URI
    http://hdl.handle.net/20.500.11937/27722
    Collection
    • Curtin Research Publications
    Abstract

    This paper reports the results of an experimental program on the effect of fly ash, slag and silica fume used as partial replacement of ordinary Portland cement (OPC) in retarding the corrosion of steel in medium-scale reinforced concrete beams. Eight reinforce concrete beams measuring 2.5 meters in length and 210 x 300 mm in cross-section were cast, four of which were subjected to accelerated corrosion. It was found that concrete containing fly ash, slag and silica fume showed better corrosion protection of steel in RC beams than OPC concrete. Among these, fly ash concrete showed the best performance in terms of lowest corrosion current (hence lowest steel loss), least visual damage and lowest tendency for delamination as measured by a concrete-embeddable fibre optic strain sensor. Corroded and un-corroded RC beams were tested under four point bending in order to evaluate the effect of corrosion damage on flexural behaviour of the beams. The results showed that corroded RC beam containing fly ash lost only 3% of its ultimate load capacity compared to 13% strength loss observed in the corroded OPC concrete beam.

    Related items

    Showing items related by title, author, creator and subject.

    • Fiber Optic Sensing for Monitoring Corrosion-Induced Damage
      Maalej, M.; Ahmed, Shaikh; Kuang, K.; Paramasivam, P. (2004)
      This paper reports the feasibility of using embedded Fabry–Pé rot fiber optic sensors to detect and monitor the propagation of cracks and delamination within concrete beams induced by corrosion of the reinforcing bars. ...
    • Estimation of electrochemical noise impedance and corrosion rates from electrochemical noise measurements.
      Lowe, Alexander M. (2002)
      Electrochemical noise refers to the spontaneous fluctuations in potential and current that can be observed on a corroding metal. The use of electrochemical noise for obtaining information on the corrosion process generates ...
    • Corrosion durability of reinforcing steel in cracked high performance fibre-reinforced cementitious composite beams
      Shaikh, Faiz; Mihashi, H.; Kobayakawa, A. (2014)
      This paper reports test results on the corrosion durability of reinforcing steel in three series of precracked beams of ordinary mortar; a high-performance fiber-reinforced cementitious composite (HPFRCC) containing ...
    Advanced search

    Browse

    Communities & CollectionsIssue DateAuthorTitleSubjectDocument TypeThis CollectionIssue DateAuthorTitleSubjectDocument Type

    My Account

    Admin

    Statistics

    Most Popular ItemsStatistics by CountryMost Popular Authors

    Follow Curtin

    • 
    • 
    • 
    • 
    • 

    CRICOS Provider Code: 00301JABN: 99 143 842 569TEQSA: PRV12158

    Copyright | Disclaimer | Privacy statement | Accessibility

    Curtin would like to pay respect to the Aboriginal and Torres Strait Islander members of our community by acknowledging the traditional owners of the land on which the Perth campus is located, the Whadjuk people of the Nyungar Nation; and on our Kalgoorlie campus, the Wongutha people of the North-Eastern Goldfields.