dc.description.abstract

The presence of furan derivatives in aged-transformer oil has been one of the key indicators for solid dielectric deterioration. Identification and quantification of furan derivatives are currently performed using high performance liquid chromatography (HPLC) or gas chromatography-mass spectrometry (GC/MS) based on ASTM D5837 standard. Although these techniques are well developed, they call for an expert personal to conduct the test and to analyse its results. Moreover, the test is relatively expensive and the analysis of oil sample may take days as most utilities sending transformer oil samples to external laboratories to be tested. This paper introduces a novel approach to determine the furan concentration within power transformer dielectric oil through ultraviolet to visible (UV-Vis) spectroscopic analysis for oil samples. Furan concentration in transformer oil would determine the absorption intensity in UV-Vis spectral range and hence the correlation between furan concentration and spectral response of transformer oil can be identified. Experimental results show that the new technique is reliable, economic and easy to be implemented on site to identify the furan concentration level in transformer oil instantly.

dc.publisherInstitut Teknologi Sepuluh Nopember (ITS)
dc.relation.urihttp://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=6360195
dc.titleNew Approach to Estimate Furan Contents in Transformer Oil Using Spectroscopic Analysis
dc.typeConference Paper
dcterms.source.titleProceedings of the 22nd Australasian Universities Power Engineering Conference
dcterms.source.seriesProceedings of the 22nd Australasian Universities Power Engineering Conference
dcterms.source.isbn9781921897078
dcterms.source.conference22nd Australasian Universities Power Engineering Conference
dcterms.source.conference-start-dateSep 26 2012
dcterms.source.conferencelocationBali, Indonesia
dcterms.source.placeBali, Indonesia
curtin.note

Copyright © 2012 IEEE. Personal use of this material is permitted. Permission from IEEEmust be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.

curtin.departmentDepartment of Electrical and Computer Engineering
curtin.accessStatusOpen access


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record