dc.description.abstract

A facile wet-chemical method was developed to prepare a novel Pt nanoparticle-loaded carbon nanofiber (Pt/CNF) electrode. Without using any stabilizer or pretreatment procedure, large amounts of Pt nanoparticles could be well deposited on the surface of the electrospun CNF electrode at room temperature, as revealed by scanning electron microscopy (SEM). The effect of the precursor concentration on the formation of Pt catalysts was investigated to optimize the performance of the proposed hybrid electrode. When applied to the electrochemical detection of hydrogen peroxide (H2O2), the Pt/CNF electrode exhibited low overpotential, fast response and high sensitivity. A low detection limit of 0.6 μM with wide linear range of 1–800 μM (R = 0.9991) was achieved at the Pt/CNF electrode, which was superior to that obtained with other H2O2 electrochemical sensors reported previously. In addition, the Pt/CNF electrode showed good selectivity for H2O2 detection in the presence of ascorbic acid (AA), acetaminophenol (AP) and uric acid (UA) under physiological pH condition. The attractive analytical performances and facile preparation method made this novel hybrid electrode promising for the development of effective H2O2 sensors.

dc.publisherElsevier BV
dc.subjectH2O2
dc.subjectelectrode
dc.subjectElectrochemical sensor
dc.subjectPt nanoparticle-loaded carbon nanofiber
dc.titleA novel and simple route to prepare a Pt nanoparticle-loaded carbon nanofiberelectrode for hydrogen peroxide sensing
dc.typeJournal Article
dcterms.source.volume26
dcterms.source.startPage4585
dcterms.source.endPage4590
dcterms.source.issn0956-5663
dcterms.source.titleBiosensors and Bioelectronics
curtin.accessStatusFulltext not available