Show simple item record

dc.contributor.authorShah, Milinkumar
dc.contributor.authorMayne, J.
dc.contributor.authorUtikar, Ranjeet
dc.contributor.authorTade, Moses
dc.contributor.authorPareek, Vishnu
dc.date.accessioned2017-01-30T13:15:27Z
dc.date.available2017-01-30T13:15:27Z
dc.date.created2011-06-20T20:01:36Z
dc.date.issued2010
dc.identifier.citationShah, Milinkumar T. and Mayne, Jeff and Utikar, Ranjeet P. and Tade, Moses O. and Pareek, Vishnu K. 2010. Gas-solid flow hydrodynamics of an industrial scale catalyst lift engager. Chemical Engineering Journal. 159 (1-3): pp. 138-148.
dc.identifier.urihttp://hdl.handle.net/20.500.11937/29815
dc.identifier.doi10.1016/j.cej.2010.01.055
dc.description.abstract

This study characterizes the hydrodynamics of an industrial scale lift engager which circulates the catalyst between the reactor and regenerator sections of a continuous catalytic reformer in an oil refinery. The flow of Geldart D particles in this unit was simulated using a granular Eulerian model. Before studying the influence of the operating parameters, the effect of several model parameters such as the drag and the frictional pressure models on the predictions was carried out. Whilst all of the drag models investigated in this study (Gidaspow and Syamlal–O’Brien models) gave qualitatively similar results, the choice of the frictional pressure model affected the simulation results in a rather astounding manner. The KTGF based frictional pressure model gave inconsistent results as both catalyst velocity and its volume fraction increased along the lift line.However, the Johnson and Jackson model overcame this drawback. Interestingly, both KTGF based and Johnson and Jackson models gave similar results for the flow inside a simple riser. Therefore, it can be concluded that for complex flow domains having both dilute and dense phase flows, the most widely used KTGF model may not be appropriate and Johnson and Jackson model should be used instead. After optimizing the selection of model parameters, simulations were conducted to study the effect of the lift gas velocity. It was observed that a lower lift gas velocity leads to large-scale fluctuations in the outlet mass flow rate. The simulation results were also compared with the previously reported studies on the riser flow with a reasonable qualitative agreement.

dc.publisherElsevier BV
dc.subjectGas–solid flow modelling
dc.subjectEulerian–Eulerian approach
dc.subjectLift engager
dc.subjectFrictional pressure
dc.subjectDrag
dc.titleGas-solid flow hydrodynamics of an industrial scale catalyst lift engager
dc.typeJournal Article
dcterms.source.volume159
dcterms.source.number1-3
dcterms.source.startPage138
dcterms.source.endPage148
dcterms.source.issn13858947
dcterms.source.titleChemical Engineering Journal
curtin.departmentDepartment of Chemical Engineering
curtin.accessStatusFulltext not available


Files in this item

Thumbnail

This item appears in the following Collection(s)