Show simple item record

dc.contributor.authorCampbell, Amity
dc.contributor.authorLloyd, D.
dc.contributor.authorAlderson, J.
dc.contributor.authorElliott, B.
dc.date.accessioned2017-01-30T13:19:29Z
dc.date.available2017-01-30T13:19:29Z
dc.date.created2016-09-12T08:36:26Z
dc.date.issued2009
dc.identifier.citationCampbell, A. and Lloyd, D. and Alderson, J. and Elliott, B. 2009. MRI development and validation of two new predictive methods of glenohumeral joint centre location identification and comparison with established techniques. Journal of Biomechanics. 42 (10): pp. 1527-1532.
dc.identifier.urihttp://hdl.handle.net/20.500.11937/30410
dc.identifier.doi10.1016/j.jbiomech.2009.03.039
dc.description.abstract

Identification of the centre of the glenohumeral joint (GHJ) is essential for three-dimensional (3D) upper limb motion analysis. A number of convenient, yet un-validated methods are routinely used to estimate the GHJ location in preference to the International Society of Biomechanics (ISB) recommended methods. The current study developed a new regression model, and simple 3D offset method for GHJ location estimation, employing easy to administer measures, and compared the estimates with the known GHJ location measured with magnetic resonance imaging (MRI). The accuracy and reliability of the new regression and simple 3D offset techniques were compared with six established predictive methods. Twenty subjects wore a 3D motion analysis marker set that was also visible in MRI. Immediately following imaging, they underwent 3D motion analysis acquisition. The GHJ and anatomical landmark positions of 15 participants were used to determine the new regression and simple 3D generic offset methods. These were compared for accuracy with six established methods using 10 subject's data. A cross validation on 5 participants not used for regression model development was also performed. Finally, 10 participants underwent a further two MRI's and subsequent 3D motion analysis analyses for inter-tester and intra-tester reliability quantification. When compared with any of the other established methods, our newly developed regression model found an average GHJ location closer to the actual MRI location, having an GHJ location error of 13±2 mm, and had significantly lower inter-tester reliability error, 6±4 mm (p<0.01). © 2009 Elsevier Ltd. All rights reserved.

dc.publisherPergamon Press
dc.titleMRI development and validation of two new predictive methods of glenohumeral joint centre location identification and comparison with established techniques
dc.typeJournal Article
dcterms.source.volume42
dcterms.source.number10
dcterms.source.startPage1527
dcterms.source.endPage1532
dcterms.source.issn0021-9290
dcterms.source.titleJournal of Biomechanics
curtin.departmentSchool of Physiotherapy and Exercise Science
curtin.accessStatusFulltext not available


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)