Show simple item record

dc.contributor.authorLin, GongQi
dc.contributor.authorSoh, Sieteng
dc.contributor.authorChin, K.
dc.date.accessioned2017-01-30T13:21:08Z
dc.date.available2017-01-30T13:21:08Z
dc.date.created2015-05-22T08:32:24Z
dc.date.issued2015
dc.identifier.citationLin, G. and Soh, S. and Chin, K. 2015. Energy-aware traffic engineering with reliability constraint. Computer Communications. 57: pp. 115-128.
dc.identifier.urihttp://hdl.handle.net/20.500.11937/30725
dc.identifier.doi10.1016/j.comcom.2014.10.002
dc.description.abstract

Current network infrastructures are over-provisioned to increase their resilience against resource failures. Such strategies exhibit poor energy efficiency during off-peak periods. In this respect, energy aware Traffic Engineering (TE) solutions aim to maximally switch off redundant network resources when traffic load is low. However, these green TE solutions do not consider their effects on network fault-tolerance. In this paper, we first aim to quantify the effects of five recently proposed green routing approaches, namely FGH, GreenTE, MSPF, SSPF, and TLDP, on the following two reliability measures: (i) terminal reliability (TR), and (ii) route reliability (RR). Experiments using three topologies with real and synthetic traffic demands show that green approaches that switch off redundant links affect TR and RR significantly. Specifically, routing traffic through multiple paths impacts reliability less while reducing energy, especially when the paths are link disjoint. Interestingly, TLDP and MSPF have better route reliability than using shortest path (SP) routing. We then formulate a problem, called reliable energy-aware-routing (R-EAR), which aims to maximally switch-off network cables subject to link utilization as well as TR/RR require- ment. We also propose an effective algorithm, called reliable Green-Routing (R-GR), to solve R-EAR. Evaluation on three real topologies shows that R-GR can save energy while satisfying both reliability and link utilization requirements. Specifically, for the GEANT network, R-GR saves up to 25.65% in energy usage without reducing RR, and saves up to 48.65% whilst reducing its average RR only by 9.1%. For the same network, our solution achieved an energy saving of 28.38% while reducing its average TR by only 8.5%.

dc.publisherElsevier Science
dc.subjectTwo link disjoint paths
dc.subjectReliability
dc.subjectBundled links
dc.subjectMultiple paths
dc.subjectEnergy-aware routing
dc.titleEnergy-aware traffic engineering with reliability constraint
dc.typeJournal Article
dcterms.source.volume57
dcterms.source.startPage115
dcterms.source.endPage128
dcterms.source.issn01403664
dcterms.source.titleComputer Communications
curtin.departmentDepartment of Computing
curtin.accessStatusFulltext not available


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record