Show simple item record

dc.contributor.authorDieterich, Angela
dc.contributor.authorPickard, Christine
dc.contributor.authorStrauss, Geoff
dc.contributor.authorDeshon, Louise
dc.contributor.authorGibson, William
dc.contributor.authorMcKay, Jan
dc.date.accessioned2017-01-30T13:22:38Z
dc.date.available2017-01-30T13:22:38Z
dc.date.created2015-02-03T20:00:39Z
dc.date.issued2014
dc.identifier.citationDieterich, A. and Pickard, C. and Strauss, G. and Deshon, L. and Gibson, W. and McKay, J. 2014. Muscle thickness measurements to estimate gluteus mediusand minimus activity levels. Manual Therapy. 19 (5): pp. 453-460.
dc.identifier.urihttp://hdl.handle.net/20.500.11937/30965
dc.identifier.doi10.1016/j.math.2014.04.014
dc.description.abstract

The clinical assessment of gluteus medius and minimus force sharing requires non-invasive measurements of individual activity levels. Do ultrasound measurements of change of muscle thickness substitute invasive electromyography (EMG)? Isometric hip abduction in 20–80% maximal voluntary isometric contraction (MVIC) was measured using dynamometry, M-mode ultrasound for gluteus medius and minimus thickness and EMG using (1) surface electrodes on gluteus medius, n = 15, (2) fine-wire electrodes in deep gluteus medius and minimus, n = 6. Gluteus medius thickened by 5.0 (SD 2.5) mm at 80% MVIC while gluteus minimus thickness was constant in the surface EMG study and decreased by 1.6 (SD 1.6) mm at the more ventral location in the fine-wire EMG study. Thickness change of gluteus medius enabled prediction of torque (r2 0.66) and of surface EMG amplitude (r2 0.57). Surface EMG enabled higher torque prediction (r2 0.84) than thickness change. Thickness change of gluteus minimus did not enable a practically relevant estimation of torque production. Ultrasound examination revealed a differential thickening behaviour of gluteus medius and minimus which enabled estimation of isometric torque production only for gluteus medius but with lower precision than surface EMG.

dc.publisherChurchill Livingstone
dc.subjectMuscle
dc.subjectElectromyography
dc.subjectUltrasound
dc.subjectHip
dc.titleMuscle thickness measurements to estimate gluteus mediusand minimus activity levels
dc.typeJournal Article
dcterms.source.volume19
dcterms.source.number5
dcterms.source.startPage453
dcterms.source.endPage460
dcterms.source.issn1356-689X
dcterms.source.titleManual Therapy
curtin.note

NOTICE: this is the author’s version of a work that was accepted forpublication in the journal Manual Therapy. Changes resulting fromthe publishing process, such as peer review, editing, corrections,structural formatting, and other quality control mechanisms may notbe reflected in this document. Changes may have been made to thiswork since it was submitted for publication. A definitive version wassubsequently published in the journal Manual Therapy, Vol.19(2014). DOI: http://doi.org/10.1016/j.math.2014.04.014

curtin.departmentSchool of Physiotherapy and Exercise Science
curtin.accessStatusOpen access


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record