    Validation of GPS and accelerometer technology in swimming

    Access Status
    Fulltext not available
    Authors
    Beanland, E.
    Main, L.
    Aisbett, B.
    Gastin, P.
    Netto, Kevin
    Date
    2014
    Type
    Journal Article
    
    Metadata
    Show full item record
    Citation
    Beanland, E. and Main, L. and Aisbett, B. and Gastin, P. and Netto, K. 2014. Validation of GPS and accelerometer technology in swimming. Journal of Science and Medicine in Sport. 17 (2): pp. 234-238.
    Source Title
    Journal of Science and Medicine in Sport
    DOI
    10.1016/j.jsams.2013.04.007
    ISSN
    1440-2440
    URI
    http://hdl.handle.net/20.500.11937/32575
    Collection
    • Curtin Research Publications
    Abstract

    Objectives: To evaluate the validity of an integrated accelerometer and Global Positioning System (GPS) device to quantify swimming kinematics variables in swimming. Design: Criterion validation study. Methods: Twenty-one sub-elite swimmers completed three 100 m efforts (one butterfly, breaststroke and freestyle) in an outdoor 50 m Olympic pool. A GPS device with an integrated tri-axial accelerometer was used to obtain mid-pool velocity and stroke count of each effort. This data was compared to velocity and stroke count data obtained from concurrently recorded digital video of the performance. Results: A strong relationship was detected between the accelerometer stroke count and the video criterion measure for both breaststroke (r > 0.98) and butterfly (r > 0.99). Also, no significant differences were detected between the GPS velocity and video obtained velocity for both freestyle and breaststroke. There was a significant difference between the GPS velocity and criterion measure for butterfly. Acceptable standard error and 95% limits of agreement were obtained for freestyle (0.13 m s-1, 0.36 m s-1) and breaststroke (0.12 m s-1, 0.33 m s-1) compared to butterfly (0.18 m s-1, 0.50 m s-1). Relative error measurements ranged between 10.2 and 13.4% across the three strokes. Conclusions: The integrated accelerometer and GPS device offers a valid and accurate tool for stroke count quantification in breaststroke and butterfly as well as measuring mid-pool swimming velocity in freestyle and breaststroke. The application of GPS technology in the outdoor training environment suggests advantageous practical benefits for swimmers, coaches and sports scientists.

    Related items

    Showing items related by title, author, creator and subject.

    • Validity of self-reported versus hospital-coded diagnosis of stroke: A cross-sectional and longitudinal study
      Jamrozik, E.; Hyde, Z.; Alfonso, Helman; Flicker, L.; Almeida, O.; Yeap, B.; Norman, P.; Hankey, G.; Jamrozik, K. (2014)
      Background: Population-based studies, as well as clinicians, often rely on self-report and hospital records to obtain a history of stroke. This study aimed to compare the validity of the diagnosis of stroke by self-report ...
    • Validity of self-reported measures of workplace sitting time and breaks in sitting time
      Clark, B.; Thorp, A.; A.H. Winkler, E.; Gardiner, P.; Healy, Genevieve; Owen, N.; Dunstan, D. (2011)
      Purpose: To understand the prevalence and potential health effect of prolonged workplace sedentary (sitting) time, valid measures are required. Here, we examined the criterion validity of a brief self-reported measure of ...
    • Investigation of pressure and saturation effects on elastic parameters: an integrated approach to improve time-lapse interpretation
      Grochau, Marcos Hexsel (2009)
      Time-lapse seismic is a modern technology for monitoring production-induced changes in and around a hydrocarbon reservoir. Time-lapse (4D) seismic may help locate undrained areas, monitor pore fluid changes and identify ...
    Advanced search

    Browse

    Communities & CollectionsIssue DateAuthorTitleSubjectDocument TypeThis CollectionIssue DateAuthorTitleSubjectDocument Type

    My Account

    Admin

    Statistics

    Most Popular ItemsStatistics by CountryMost Popular Authors

    Follow Curtin

    • 
    • 
    • 
    • 
    • 

    CRICOS Provider Code: 00301JABN: 99 143 842 569TEQSA: PRV12158

    Copyright | Disclaimer | Privacy statement | Accessibility

    Curtin would like to pay respect to the Aboriginal and Torres Strait Islander members of our community by acknowledging the traditional owners of the land on which the Perth campus is located, the Whadjuk people of the Nyungar Nation; and on our Kalgoorlie campus, the Wongutha people of the North-Eastern Goldfields.