Abstract
The aim of this study was to investigate the effect of multislice CT scanning protocol on the visualization of fenestrated vessel stents in patients with abdominal aortic aneurysms (AAA) treated with fenestrated endovascular grafts.PURPOSE: The aim of this study was to investigate the effect of multislice CT scanning protocol on the visualization of fenestrated vessel stents in patients with abdominal aortic aneurysms (AAA) treated with fenestrated endovascular grafts.. METHOD AND MATERIALS: 21 patients with AAA undergoing fenestrated endovascular repair were included in the study. Multislice CT angiography was performed with variable protocols and the section thickness used in each scanning protocol was identified with the aim of studying the relationship between slice thickness and imaging appearance of fenestrated vessel stents visualized on 2D axial, multiplanar reformatted and 3D virtual intravascular endoscopy images. Image quality was assessed based on the degree of artifacts and their effect on the visualization of fenestrated stents. RESULTS: There were seven different multislice CT scanning protocols in the 21 patients (25 datasets with 4 follow-ups in 4 patients). The slice thickness included 0.5 mm, 0.625 mm, 1.0 mm, 1.25 mm, 2.5 mm, 3.0 mm and 5.0 mm, respectively. Of these CT protocols, images (especially 2D/3D reconstructions) acquired with 2.5 mm, 3.0 mm and 5.0 mm were found to be significantly compromised due to the interference of artifacts. Images acquired with a slice thickness of 1.0 mm or 1.25 mm were scored equally or lower than those acquired with submillimetre section thickness (0.5 mm and 0.625 mm) with minor degree of artifacts resulting in acceptable image quality.CONCLUSION: Our results showed that multislice CT scanning protocols with a submillimetre slice thickness are not necessary for evaluation of fenestrated repair of AAA as protocols with a slice thickness of 1.0 mm or 1.25 mm produced similar image quality to those with a section thickness of 0.5 mm or 0.625 mm. CLINICAL RELEVANCE/APPLICATION: The research findings of this study are valuable for endovascular specialists to choose appropriate multislice CT protocols in the follow-up of fenestrated endovascular repair of AAA.
Related items
Showing items related by title, author, creator and subject.
-
Sun, Zhonghua; Allen, Yvonne; Mwipatayi, B.; Hartley, D.; Lawrence-Brown, Michael (2008)Purpose: To investigate the effect of multislice computed tomography (CT) protocols on the visualization of target vessel stents in patients with treated with fenestrated endovascular grafts.Methods: Twenty-one patients ...
-
Sun, Zhonghua; Mwipatayi, B.; Allen, Yvonne; Hartley, D.; Lawrence-Brown, M. (2008)Objective: The purpose of this article is to provide 2D and 3D imaging appearances of fenestrated endovascular repair of abdominal aortic aneurysms (AAA) based on multislice CT angiography.Methods and Results: 14 patients ...
-
Sun, Zhonghua; Allen, Yvonne; Sanjay, N.; Knight, R.; Hartley, D.; Lawrence-Brown, M. (2008)Purpose: To report the diagnostic value of computed tomographic (CT) virtual intravascular endoscopy (VIE) in the assessment of patients with abdominal aortic aneurysm (AAA) treated with fenestrated endovascular grafts.Methods: ...