Curtin University Homepage
  • Library
  • Help
    • Admin

    espace - Curtin’s institutional repository

    JavaScript is disabled for your browser. Some features of this site may not work without it.
    View Item 
    • espace Home
    • espace
    • Curtin Research Publications
    • View Item
    • espace Home
    • espace
    • Curtin Research Publications
    • View Item

    Mass discrimination during MC-ICPMS isotopic ratio measurements: investigation by means of synthetic isotopic mixtures (IRMM-007 series) and application to the calibration of natural-like zinc materials (including IRMM-3702 and IRMM-651)

    Access Status
    Fulltext not available
    Authors
    Ponzevera, E.
    Quetal, C.
    Evans, P.
    Berglund, M.
    Loss, Robert
    Fortunato, G.
    Taylor, P.
    Date
    2006
    Type
    Journal Article
    
    Metadata
    Show full item record
    Citation
    Ponzevera, Emmanuel and Quetel, Christophe R. and Evans, Peter and Berglund, Michael and Loss, Robert D. and Fortunato, Giuseppino and Taylor, Philip D. P.. 2006. Mass discrimination during MC-ICPMS isotopic ratio measurements: investigation by means of synthetic isotopic mixtures (IRMM-007 series) and application to the calibration of natural-like zinc materials (including IRMM-3702 and IRMM-651). Journal of the American Society for Mass Spectrometry 17 (10): 1413-1428.
    Source Title
    Journal of the American Society for Mass Spectrometry
    DOI
    10.1016/j.jasms.2006.06.001
    Faculty
    Division of Engineering, Science and Computing
    Department of Medical Imaging Science
    Faculty of Science
    School
    Department of Imaging and Applied Physics
    URI
    http://hdl.handle.net/20.500.11937/33868
    Collection
    • Curtin Research Publications
    Abstract

    Calibration of mass spectrometry (MS) isotope ratio measurement results by means of gravimetrically prepared isotopic mixtures is a long known way of anchoring isotopic values to the SI system. Thermal ionisation (TI) MS is the technique traditionally associated with this strategy, while multi-collector double focusing inductively coupled plasma (MC-ICP) ? MS, with a flexible ion source operated at atmospheric pressure and the possibility to achieve 0.01% or less repeatability on isotope ratio measurements, now appears to be an attractive alternative. However, this absolute calibration strategy necessitates that mass discrimination effects remain invariant in time (at least during the duration of all the experiments) and across the range of isotope ratios measured, which is not the case with MC-ICPMS measurements. This issue is illustrated here with Zn isotopic measurements obtained using locally produced synthetic Zn isotope mixtures. The necessary adjustments to specific characteristics of MC-ICPMS are described. Firstly, variations in the mass discrimination effects across the measurement sequence are propagated as an uncertainty component. Secondly, linear proportionality during each individual measurement between normalised mass discrimination and the average mass of the isotope ratios is used to evaluate mass discrimination for the ratios involving 66Zn and 70Zn. Thirdly, linear proportionality after iterative calculations between mass discrimination and the isotope ratio values for n(67Zn)/n(64Zn) and n(68Zn)/n(64Zn) in the mixtures is used to evaluate mass discrimination for the same ratios but specific to the isotopically enriched materials, and additional iterations are introduced until the last significant digit in the isotope ratios in the mixtures is stabilised. Fourthly, ratios in final unknown materials (various natural Zn solutions, including IRMM-3702 and IRMM-651) are calibrated by external bracketing using the isotopic mixtures.The relative expanded uncertainty (k = 2) estimated for n(68Zn)/n(64Zn) and n(67Zn)/n(64Zn) ratio values in the synthetic isotopic mixtures and the natural zinc samples was in the range of 0.034 - 0.048%. The uncertainty on the weighing (r.s.u. = 0.01%, k = 1) was by far the major contributor to the total budget, followed by the uncertainty on the correction for the impurity content in the enriched materials. The effect of the repeatability on isotope ratio measurements was minimal (=2% of the total uncertainty budget). This work was further validated from the agreement achieved for the same set of samples between these results and those obtained with a single detector TIMS (much larger uncertainty estimates) and with another MC-ICP-MS.The absolute isotope ratio values found for the candidate isotopic certified reference material IRMM-3702 ? also proposed as ?Delta 0? for delta-scale isotopic measurements ? were n(66Zn)/n(64Zn) = 0.56397(30), n(67Zn)/n(64Zn) = 0.082166(36), n(68Zn)/n(64Zn) = 0.37519(13) and n(70Zn)/n(64Zn) = 0.012422(24). The derived Zn atomic weight value Ar(Zn) = 65.37778 (22) differs significantly from the current IUPAC value by Chang et al.[ ]. Re-measurement with the IRMM-007 series of synthetic isotopic mixtures of the Zn isotope ratios in the natural material measured by Chang et al. [1] have revealed also large systematic differences (1.73% to 5.6%) that suggest unrecognized measurement biases in their results.

    Related items

    Showing items related by title, author, creator and subject.

    • Rapid, high-precision measurements of boron isotopic compositions in marine carbonates
      McCulloch, M.; Holcomb, M.; Rankenburg, Kai; Trotter, J. (2014)
      Copyright © 2014 John Wiley & Sons, Ltd. RATIONALE The isotopic composition and elemental abundance of boron (B) in marine carbonates provide a powerful tool for tracking changes in seawater pH and carbonate chemistry. ...
    • Isotope fractionation studies of molybdenum
      Wieser, M.; De Laeter, John; Varner, M. (2007)
      Mass spectrometric studies of the isotopic composition of molybdenum have become an active area of research in stable isotope geochemistry, biogeochemistry and cosmochemistry. The redox chemistry of Mo, together with its ...
    • LGC-1: A zircon reference material for in-situ (U-Th)/He dating
      Tian, Y.; Vermeesch, P.; Danisik, Martin; Condon, D.; Chen, W.; Kohn, B.; Schwanethal, J.; Rittner, M. (2017)
      A pairwise in-situ (U-Th)/He dating method has been proposed for mitigating matrix-related bias in U and Th measurements using synthetic reference materials. This method requires a natural zircon reference material whose ...
    Advanced search

    Browse

    Communities & CollectionsIssue DateAuthorTitleSubjectDocument TypeThis CollectionIssue DateAuthorTitleSubjectDocument Type

    My Account

    Admin

    Statistics

    Most Popular ItemsStatistics by CountryMost Popular Authors

    Follow Curtin

    • 
    • 
    • 
    • 
    • 

    CRICOS Provider Code: 00301JABN: 99 143 842 569TEQSA: PRV12158

    Copyright | Disclaimer | Privacy statement | Accessibility

    Curtin would like to pay respect to the Aboriginal and Torres Strait Islander members of our community by acknowledging the traditional owners of the land on which the Perth campus is located, the Whadjuk people of the Nyungar Nation; and on our Kalgoorlie campus, the Wongutha people of the North-Eastern Goldfields.