dc.identifier.citationVeder, Jean-Pierre and De Marco, Roland and Clarke, Graeme and Chester, Ryan and Nelson, Andrew and Prince, Kathryn and Pretsch, Ern and Bakker, Eric. 2008. Elimination of Undesirable Water Layers in Solid-Contact Polymeric Ion-Selective Electrodes. Analytical Chemistry 80 (17): 6731-6740.
dc.identifier.urihttp://hdl.handle.net/20.500.11937/34161
dc.identifier.doi10.1021/ac800823f
dc.description.abstract

This study aimed to develop a novel approach for the production of analytically robust and miniaturized polymeric ion sensors that are vitally important in modern analytical chemistry (e.g., clinical chemistry using single blood droplets, modern biosensors measuring clouds of ions released from nanoparticle-tagged biomolecules, laboratory-on-a-chip applications, etc.). This research has shown that the use of a water-repellent poly(methyl methacrylate)/poly(decyl methacrylate) (PMMA/PDMA) copolymer as the ion-sensing membrane, along with a hydrophobic poly(3-octylthiophene 2,5-diyl) (POT) solid contact as the ion-to-electron transducer, is an excellent strategy for avoiding the detrimental water layer formed at the buried interface of solid-contact ion-selective electrodes (ISEs). Accordingly, it has been necessary to implement a rigorous surface analysis scheme employing electrochemical impedance spectroscopy (EIS), in situ neutron reflectometry/EIS (NR/EIS), secondary ion mass spectrometry (SIMS), and small-angle neutron scattering (SANS) to probe structurally the solid-contact/membrane interface, so as to identify the conditions that eliminate the undesirable water layer in all solid-state polymeric ion sensors. In this work, we provide the first experimental evidence that the PMMA/PDMA copolymer system is susceptible to water ?pooling? at the interface in areas surrounding physical imperfections in the solid contact, with the exposure time for such an event in a PMMA/PDMA copolymer ISE taking nearly 20 times longer than that for a plasticized poly(vinyl chloride) (PVC) ISE, and the simultaneous use of a hydrophobic POT solid contact with a PMMA/PDMA membrane can eliminate totally this water layer problem.

dc.publisherAmerican Chemical Society
dc.titleElimination of Undesirable Water Layers in Solid-Contact Polymeric Ion-Selective Electrodes
dc.typeJournal Article
dcterms.source.volume80
dcterms.source.number17
dcterms.source.monthaug
dcterms.source.startPage6731
dcterms.source.endPage6740
dcterms.source.titleAnalytical Chemistry
curtin.departmentNanochemistry Research Institute (Research Institute)
curtin.identifierEPR-3033
curtin.accessStatusFulltext not available
curtin.facultyNanochemistry Research Centre


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record