Show simple item record

dc.contributor.authorMelloh, Markus
dc.contributor.authorTheis, J.
dc.contributor.authorBeneke, R.
dc.date.accessioned2017-01-30T13:48:45Z
dc.date.available2017-01-30T13:48:45Z
dc.date.created2015-12-10T04:26:12Z
dc.date.issued2012
dc.identifier.citationMelloh, M. and Theis, J. and Beneke, R. 2012. Variability of blood lactate during and between given constant prolonged cycling power. Journal of Sports Medicine and Physical Fitness. 52 (6): pp. 575-582.
dc.identifier.urihttp://hdl.handle.net/20.500.11937/35275
dc.description.abstract

Aim. Blood lactate concentration (BLC) has been the basis of rational performance diagnostics for almost five decades. Aim of this study was to identify the variability of the BLC during repeated constant power tests (VC-BLC) and to quantify the corresponding variability of changes in the BLC over time (VC-BLC-Difference). Methods. Twelve healthy male subjects (24.8±3-8 years, 182.9±7.5 cm, 75.7±7.1 kg,VO 2peak: 4.1±0.61 min-1) performed four series of three constant power tests at exercise intensities of 45% (A), 60% (B), 75% (C) and 90% (D) of VO2peak. Blood sampling was conducted before, at the end of every 5th min and at the end of each test terminated ahead of schedule. Results. BLC was different at all exercise intensities from minute five onwards. Power output was equivalent to 142.1±18.9 W (A), 196.3±25.2 W (B), 247.9±30.3 W (C) and 302.5±38.4 W (D). VC-BLC varied between 9±2.2% and 21±10.1%. VC-BLC and VC-BLC-Difference between 10th and 30th min correlated inversely with mean BLC level and BLC-Difference respectively. Conclusion. By providing first data on constant power test VC-BLC and VC-BLC-Difference this study might help to improve performance diagnostics and training control in sports medicine and medical exercise therapy by assisting in selecting and monitoring exercise intensity. Performance monitoring with BLC-Differences is feasible at moderate and high exercise intensities; single BLC measurements at termination of tests might not be sufficient.

dc.titleVariability of blood lactate during and between given constant prolonged cycling power
dc.typeJournal Article
dcterms.source.volume52
dcterms.source.number6
dcterms.source.startPage575
dcterms.source.endPage582
dcterms.source.issn0022-4707
dcterms.source.titleJournal of Sports Medicine and Physical Fitness
curtin.departmentCurtin Medical School
curtin.accessStatusFulltext not available


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record