Show simple item record

dc.contributor.authorFereidouni, Alireza
dc.contributor.authorMasoum, M.
dc.contributor.authorMoghbel, Moayed
dc.date.accessioned2017-01-30T13:48:48Z
dc.date.available2017-01-30T13:48:48Z
dc.date.created2016-03-07T19:30:17Z
dc.date.issued2015
dc.identifier.citationFereidouni, A. and Masoum, M. and Moghbel, M. 2015. Power Quality Improvement Using an Enhanced Network-Side-Shunt-Connected Dynamic Voltage Restorer. International Journal of Emerging Electric Power Systems. 16 (5): pp. 451-472.
dc.identifier.urihttp://hdl.handle.net/20.500.11937/35284
dc.identifier.doi10.1515/ijeeps-2015-0019
dc.description.abstract

Among the four basic dynamic voltage restorer (DVR) topologies, the network-side shunt-connected DVR (NSSC-DVR) has a relatively poor performance and is investigated in this paper. A new configuration is proposed and implemented for NSSC-DVR to enhance its performance in compensating (un)symmetrical deep and long voltage sags and mitigate voltage harmonics. The enhanced NSSC-DVR model includes a three-phase half-bridge semi-controlled network-side-shunt-connected rectifier and a three-phase full-bridge series-connected inverter implemented with a back-to-back configuration through a bidirectional buck-boost converter. The network-side-shunt-connected rectifier is employed to inject/draw the required energy by NSSC-DVR to restore the load voltage to its pre-fault value under sag/swell conditions. The buck-boost converter is responsible for maintaining the DC-link voltage of the series-connected inverter at its designated value in order to improve the NSSC-DVR capability in compensating deep and long voltage sags/swells. The full-bridge series-connected inverter permits to compensate unbalance voltage sags containing zero-sequence component. The harmonic compensation of the load voltage is achieved by extracting harmonics from the distorted network voltage using an artificial neural network (ANN) method called adaptive linear neuron (Adaline) strategy. Detailed simulations are performed by SIMULINK/MATLAB software for six case studies to verify the highly robustness of the proposed NSSC-DVR model under various conditions.

dc.publisherWalter de Gruyter GmbH
dc.titlePower Quality Improvement Using an Enhanced Network-Side-Shunt-Connected Dynamic Voltage Restorer
dc.typeJournal Article
dcterms.source.volume16
dcterms.source.number5
dcterms.source.startPage451
dcterms.source.endPage472
dcterms.source.issn2194-5756
dcterms.source.titleInternational Journal of Emerging Electric Power Systems
curtin.departmentDepartment of Electrical and Computer Engineering
curtin.accessStatusFulltext not available


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record