Curtin University Homepage
  • Library
  • Help
    • Admin

    espace - Curtin’s institutional repository

    JavaScript is disabled for your browser. Some features of this site may not work without it.
    View Item 
    • espace Home
    • espace
    • Curtin Research Publications
    • View Item
    • espace Home
    • espace
    • Curtin Research Publications
    • View Item

    Prosthetic alignment after total knee replacement is not associated with dissatisfaction or change in Oxford Knee Score. A multivariable regression analysis

    Access Status
    Fulltext not available
    Authors
    Huijbregts, H.
    Khan, Riaz
    Fick, Daniel
    Jarrett, O.
    Haebich, S.
    Date
    2016
    Type
    Journal Article
    
    Metadata
    Show full item record
    Citation
    Huijbregts, H. and Khan, R. and Fick, D. and Jarrett, O. and Haebich, S. 2016. Prosthetic alignment after total knee replacement is not associated with dissatisfaction or change in Oxford Knee Score. A multivariable regression analysis. The Knee. 23 (3): pp. 535-539.
    Source Title
    Knee
    DOI
    10.1016/j.knee.2015.12.007
    ISSN
    0968-0160
    School
    Department of Computing
    URI
    http://hdl.handle.net/20.500.11937/37268
    Collection
    • Curtin Research Publications
    Abstract

    Background: Approximately 18% of the patients are dissatisfied with the result of total knee replacement. However, the relation between dissatisfaction and prosthetic alignment has not been investigated before. Methods: We retrospectively analysed prospectively gathered data of all patients who had a primary TKR, preoperative and one-year postoperative Oxford Knee Scores (OKS) and postoperative computed tomography (CT). The CT protocol measures hip-knee-ankle (HKA) angle, and coronal, sagittal and axial component alignment. Satisfaction was defined using a five-item Likert scale. We dichotomised dissatisfaction by combining '(very) dissatisfied' and 'neutral/not sure'. Associations with dissatisfaction and change in OKS were calculated using multivariable logistic and linear regression models. Results: 230 TKRs were implanted in 105 men and 106 women. At one year, 12% were (very) dissatisfied and 10% neutral. Coronal alignment of the femoral component was 0.5 degrees more accurate in patients who were satisfied at one year. The other alignment measurements were not different between satisfied and dissatisfied patients. All radiographic measurements had a P-value > 0.10 on univariate analyses. At one year, dissatisfaction was associated with the three-months OKS. Change in OKS was associated with three-months OKS, preoperative physical SF-12, preoperative pain and cruciate retaining design. Discussion: Neither mechanical axis, nor component alignment, is associated with dissatisfaction at one year following TKR. Patients get the best outcome when pain reduction and function improvement are optimal during the first three months and when the indication to embark on surgery is based on physical limitations rather than on a high pain score. Level of evidence: 2.

    Related items

    Showing items related by title, author, creator and subject.

    • Patient Dissatisfaction Following Total Knee Arthroplasty: A Systematic Review of the Literature
      Gunaratne, R.; Pratt, D.; Banda, Joseph; Fick, Daniel; Khan, Riaz; Robertson, Brett (2017)
      © 2017 Elsevier Inc. Background Dissatisfaction following total knee arthroplasty (TKA) is common. Approximately 20% of patients report dissatisfaction following primary TKA. This systematic literature review explores key ...
    • A comparison of the responsiveness of 4 commonly used patient-reported outcome instruments at 5 years after matrix-induced autologous chondrocyte implantation
      Ebert, J.; Smith, Anne; Wood, D.; Ackland, T. (2013)
      Background: Patient-reported outcome (PRO) instruments are employed to assess outcomes after matrix-induced autologous chondrocyte implantation (MACI), although the PRO most responsive to change after surgery remains ...
    • The progression of isokinetic knee strength after matrix-induced autologous chondrocyte implantation: implications for rehabilitation and return to activity
      Ebert, J.; Smith, Anne; Edwards, P.; Ackland, T. (2014)
      Context: Matrix-induced autologous chondrocyte implantation (MACI) is an established technique for the repair of knee chondral defects. Despite the reported clinical improvement in knee pain and symptoms, little is known ...
    Advanced search

    Browse

    Communities & CollectionsIssue DateAuthorTitleSubjectDocument TypeThis CollectionIssue DateAuthorTitleSubjectDocument Type

    My Account

    Admin

    Statistics

    Most Popular ItemsStatistics by CountryMost Popular Authors

    Follow Curtin

    • 
    • 
    • 
    • 
    • 

    CRICOS Provider Code: 00301JABN: 99 143 842 569TEQSA: PRV12158

    Copyright | Disclaimer | Privacy statement | Accessibility

    Curtin would like to pay respect to the Aboriginal and Torres Strait Islander members of our community by acknowledging the traditional owners of the land on which the Perth campus is located, the Whadjuk people of the Nyungar Nation; and on our Kalgoorlie campus, the Wongutha people of the North-Eastern Goldfields.