Common mode voltage generated by a power converter in combination with parasitic capacitive couplings is a potential source of shaft voltage in an AC motor drive system. In this paper, a three-phase motor drive system supplied with a single-phase AC-DC diode rectifier is investigated in order to reduce shaft voltage in a three-phase AC motor drive system. In this topology, the common mode voltage generated by the inverter is influenced by the AC-DC diode rectifier because the placement of the neutral point is changing in different rectifier circuit states. A pulse width modulation technique is presented by a proper placement of the zero vectors to reduce the common mode voltage level, which leads to a cost effective shaft voltage reduction technique without load current distortion, while keeping the switching frequency constant. Analysis and simulations have been presented to investigate the proposed method.
Related items
Showing items related by title, author, creator and subject.
-
Adabi, J.; zare, F.; Ledwich, G.; Ghosh, Arindam; lorenz, R. (2008)Bearing damage in modern inverter-fed AC drive systems is more common than in motors working with 50 or 60 Hz power supply. Fast switching transients and common mode voltage generated by a PWM inverter cause unwanted shaft ...
-
Beales, Darren (2009)Aberrant motor control strategies have been identified in chronic pelvic girdle pain (PGP) subjects. It has been proposed that aberrant motor control strategies could provide a mechanism for ongoing pain and disability ...
-
Davari, P.; Yang, Y.; Zare, Firuz; Blaabjerg, F. (2016)© 1982-2012 IEEE. The majority of the industrial motor drive systems are equipped with the conventional line-commutated front-end rectifiers and being one of the main sources of harmonics in the power line. While a parallel ...