Show simple item record

dc.contributor.authorSun, Zhonghua
dc.contributor.authorChaichana, T.
dc.contributor.authorJiang, W.
dc.contributor.authorLiu, B.
dc.date.accessioned2017-01-30T15:03:04Z
dc.date.available2017-01-30T15:03:04Z
dc.date.created2008-11-12T23:36:44Z
dc.date.issued2008
dc.identifier.citationSun, Zhonghua and Chaichana, Thanapong and Jiang, Wen and Liu, Bo. 2008. Multislice CT virtual endoscopy in pre-aortic stent grafting: optimization of scanning protocols., in Sangworasil, Manas (ed), 3rd International Symposium on Biomedical Engineering, 10 Nov 2008. Bangkok, Thailand: ISBME.
dc.identifier.urihttp://hdl.handle.net/20.500.11937/42919
dc.description.abstract

The purpose of this study was to investigate the optimal scanning protocols of multislice CT (MSCT) angiography in pre-aortic stent grafting, visualized on virtual endoscopy (VE). A series of scans were performed on a human aorta phantom with a 16-slice multislice CT scanner with the scanning protocols as follows: section thickness of1.0/1.5/2.0/3.0 mm, pitch value of 1.0/1.25/1.5, and reconstruction interval of 50% overlap. Signal to noise ratio and standard deviation (SD) of the signal intensity on VE images were measured to determine the image quality in relation to MSCT scanning protocols. Subjective assessment was performed by two observers evaluating the degree ofartefacts and the configuration of the renal ostium visualized on VE images. Our results showed that the scanning protocol with a section thickness of 2.0 mm resulted in the highest SNR and lowest SD compared to other protocols (p<0.05).Subjective assessment demonstrated that VE image quality was determined by section thickness, but independent of pitch values. We recommended the scanning protocol of section thickness 2.0 mm, pitch 1.5 with a reconstruction interval of 1.0 mm as the optimal one since it allows optimal visualization of VE images of aortic ostia, fewer artefacts and less radiation dose.

dc.publisherISBME
dc.subjectimage quality
dc.subjectstandard deviation
dc.subjectvirtual endoscopy
dc.subject- Computed tomography
dc.subjectartefacts
dc.titleMultislice CT virtual endoscopy in pre-aortic stent grafting: optimization of scanning protocols.
dc.typeConference Paper
dcterms.source.titleProceedings of the 3rd International Symposium on Biomedical Engineering
dcterms.source.seriesProceedings of the 3rd International Symposium on Biomedical Engineering
dcterms.source.conference3rd International Symposium on Biomedical Engineering
dcterms.source.conference-start-date10 Nov 2008
dcterms.source.conferencelocationBangkok, Thailand
dcterms.source.placeThailand
curtin.note

This paper is to be presented at the above conference.

curtin.identifierEPR-3012
curtin.accessStatusFulltext not available
curtin.facultyFaculty of Science and Computing


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record