Show simple item record

dc.contributor.authorKele, B.
dc.contributor.authorWolfs, Peter
dc.contributor.authorTomlinson, I.
dc.contributor.authorHood, B.
dc.contributor.authorMidmore, D.
dc.contributor.editorUnknown
dc.date.accessioned2017-01-30T15:22:45Z
dc.date.available2017-01-30T15:22:45Z
dc.date.created2010-05-02T20:05:11Z
dc.date.issued2005
dc.identifier.citationKele, Ben and Wolfs, Peter and Tomlinson, Ian and Hood, Barry and Midmore, David. 2005. Greywater Reuse in a Sewered Area Design and Implementation at Research House, in Jones, M. and Patterson, R. (ed), Performance assessment for on-site systems : regulation, operation and monitoring : proceedings of On-site '05 Conference, pp. 257-264. Armidale NSW: Lanfax Laboratories.
dc.identifier.urihttp://hdl.handle.net/20.500.11937/45710
dc.description.abstract

In Queensland, the Plumbing and Drainage Act (2002) is being amended to allow greywater reuse in sewered areas. The greywater must be treated and applied in a safe manner for both public and environmental health. The Queensland State Government has built, in Rockhanlpton, a Research House as part of their 'Towards Healthy and Sustainable Housing Research Project'. Research House was built using water-efficient infrastructure and has two rainwater tanks (total capacity 7 kL). The Central Queensland University (CQU) was asked to design a greywater treatment and reuse system for the House. The proposed design incorporates a backflow prevention device on the water mains entry to the house. The harvested storm water from the rainwater tanks will provide water for the hot-water system and laundry. This will reduce the amount of potable mains water required by the house and potentially provide softer water that should reduce the scaling in the hot-water system and require lower doses of detergents.The greywater from the laundry, shower, and vanity unit will be collected and primary treated in a deep vertical greasetrap. The primary treatment tank will have an overflow to the sewer. The primary treated greywater will be filtered and then used for subsurface irrigation. Research House has an established monitoring program that will be adapted to record the volumes of harvested stormwater and greywater reuse. Water quality parameters will be examined on a monthly basis. The proposed storm water reuse and greywater treatment and reuse plan is expected to reduce the amount of reticulated mains-supplied water used by Research House by approximately 45%.

dc.publisherLanfax Laboratories
dc.subjectstormwater reuse
dc.subjectQueensland Greywater Reuse Legislation
dc.subjectPlumbing and Drainage Act 2002
dc.subjectBackflow prevention
dc.subjectrainwater tanks
dc.subjectwater efficiency
dc.titleGreywater Reuse in a Sewered Area Design and Implementation at Research House
dc.typeConference Paper
dcterms.source.startPage257
dcterms.source.endPage264
dcterms.source.titlePerformance assessment for on-site systems : regulation, operation and monitoring : proceedings of On-site '05 Conference
dcterms.source.seriesPerformance assessment for on-site systems : regulation, operation and monitoring : proceedings of On-site '05 Conference
dcterms.source.isbn0957943822
dcterms.source.conferencePerformance assessment for on-site systems : regulation, operation and monitoring : proceedings of On-site '05 Conference
dcterms.source.conference-start-dateSep 26 2005
dcterms.source.conferencelocationArmidale NSW
dcterms.source.placeArmidale NSW
curtin.accessStatusOpen access
curtin.facultyDepartment of Electrical and Computer Engineering
curtin.facultySchool of Engineering
curtin.facultyFaculty of Science and Engineering


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record