    Towards improving the robustness of electrochemical gas sensors: Impact of PMMA addition on the sensing of oxygen in an ionic liquid

    231146_231146.pdf (948.5Kb)
    Access Status
    Open access
    Authors
    Lee, J.
    Du Plessis, G.
    Arrigan, Damien
    Silvester, Debbie
    Date
    2015
    Type
    Journal Article
    
    Metadata
    Show full item record
    Citation
    Lee, J. and Du Plessis, G. and Arrigan, D. and Silvester, D. 2015. Towards improving the robustness of electrochemical gas sensors: Impact of PMMA addition on the sensing of oxygen in an ionic liquid. Analytical Methods. 7 (17): pp. 7327-7335.
    Source Title
    Analytical Methods
    DOI
    10.1039/c5ay00497g
    ISSN
    1759-9660
    School
    Nanochemistry Research Institute
    Remarks

    This open access article is distributed under the Creative Commons license http://creativecommons.org/licenses/by/3.0/

    URI
    http://hdl.handle.net/20.500.11937/46507
    Collection
    • Curtin Research Publications
    Abstract

    The electrochemical reduction of oxygen (O2) has been studied on commercially-available integrated Pt thin-film electrodes (TFEs). Chemically reversible (but electrochemically quasi-reversible) cyclic voltammetry was observed in the room temperature ionic liquid (RTIL) 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide ([C2mim][NTf2]), showing superior behaviour of TFEs compared to screen-printed electrodes for oxygen sensing. As a step towards the preparation of robust gas sensors, the RTIL was mechanically stabilised on the TFE surface by the addition of poly(methyl methacrylate) (PMMA). At a PMMA concentration in the RTIL of ca. 50% mass, electrolyte flow was not evident. O2 reduction peak currents were found to decrease systematically with increasing PMMA content, reflecting the higher viscosity of the electrolyte medium. Linear calibration graphs were obtained for 0–100% vol. oxygen at all PMMA–RTIL mixtures studied. The sensitivities decreased as [PMMA] increased, but the limits of detection were relatively unchanged. Mechanical stability of the sensors was tested in different orientations (flat, upside down, sideways) with both the neat RTIL and 50% mass electrolyte. Whilst the electrochemical responses were dramatically changed for the neat RTIL, the responses in the PMMA–RTIL mixture were independent of electrode orientation. Additionally, the oxygen response in the PMMA–RTIL mixture was less affected by atmospheric impurities and moisture, compared to the neat RTIL. This suggests that these low-cost miniaturised devices can successfully be used for oxygen sensing applications in field situations, especially where portability is essential.

    Related items

    Showing items related by title, author, creator and subject.

    • Low-cost microarray thin-film electrodes with ionic liquid gel-polymer electrolytes for miniaturised oxygen sensing
      Lee, J.; Silvester, Debbie (2016)
      A robust, miniaturised electrochemical gas sensor for oxygen (O2) has been constructed using a commercially available Pt microarray thin-film electrode (MATFE) with a gellified electrolyte containing the room temperature ...
    • Screen-Printed Graphite Electrodes as Low-Cost Devices for Oxygen Gas Detection in Room-Temperature Ionic Liquids.
      Lee, J.; Hussain, G.; Banks, C.; Silvester, Debbie (2017)
      Screen-printed graphite electrodes (SPGEs) have been used for the first time as platforms to detect oxygen gas in room-temperature ionic liquids (RTILs). Up until now, carbon-based SPEs have shown inferior behaviour ...
    • A methodology to detect explosive residues using a gelled ionic liquid based field-deployable electrochemical device
      Hay, C.E.; Lee, Juni ; Silvester-Dean, Debbie (2020)
      A simple and robust, low-cost electrochemical device is proposed for the combined sampling and detection of the trace solid explosive 2,4,6-trinitrotoluene (TNT) from a non-porous surface. Four different substrates were ...
    Advanced search

    Browse

    Communities & CollectionsIssue DateAuthorTitleSubjectDocument TypeThis CollectionIssue DateAuthorTitleSubjectDocument Type

    My Account

    Admin

    Statistics

    Most Popular ItemsStatistics by CountryMost Popular Authors

    Follow Curtin

    • 
    • 
    • 
    • 
    • 

    CRICOS Provider Code: 00301JABN: 99 143 842 569TEQSA: PRV12158

    Copyright | Disclaimer | Privacy statement | Accessibility

    Curtin would like to pay respect to the Aboriginal and Torres Strait Islander members of our community by acknowledging the traditional owners of the land on which the Perth campus is located, the Whadjuk people of the Nyungar Nation; and on our Kalgoorlie campus, the Wongutha people of the North-Eastern Goldfields.