Determination of Platinum-Group Elements and Re-Os Isotopes using ID-ICP-MS and N-TIMS from a Single Digestion after Two-Stage Column Separation
dc.contributor.author | Li, J. | |
dc.contributor.author | Jiang, X. | |
dc.contributor.author | Xu, J. | |
dc.contributor.author | Zhong, L. | |
dc.contributor.author | Wang, Xuan-Ce | |
dc.contributor.author | Wang, G. | |
dc.contributor.author | Zhao, P. | |
dc.date.accessioned | 2017-01-30T15:30:54Z | |
dc.date.available | 2017-01-30T15:30:54Z | |
dc.date.created | 2015-01-29T20:00:48Z | |
dc.date.issued | 2014 | |
dc.identifier.citation | Li, J. and Jiang, X. and Xu, J. and Zhong, L. and Wang, X. and Wang, G. and Zhao, P. 2014. Determination of Platinum-Group Elements and Re-Os Isotopes using ID-ICP-MS and N-TIMS from a Single Digestion after Two-Stage Column Separation. Geostandards and Geoanalytical Research. 38 (1): pp. 37-50. | |
dc.identifier.uri | http://hdl.handle.net/20.500.11937/47051 | |
dc.identifier.doi | 10.1111/j.1751-908X.2013.00242.x | |
dc.description.abstract |
We report an improved procedure for the determination of the platinum-group elements (PGE) and Re, and Os isotopes from a single sample aliquot by isotope dilution (ID) using inductively coupled plasma-mass spectrometry (ICP-MS) and negative thermal ionisation mass spectrometry (N-TIMS), respectively. A two-stage column method was used to purify PGE-Re from their samplematrix and interfering elements (e.g., Mo, Zr and Hf) after Os had been separated by CCl4 solvent extraction. The first column separation step used cation exchange resin (AG50W-X8) to concentrate PGE-Re and some potential interfering elements (e.g., Mo, Zr and Hf). In the second step, N-benzoyl-N-phenylhydroxylamine (BPHA) extraction resin was used to separate PGE-Re from the remaining interfering elements, which all remained strongly absorbed to the resin. The method was used todetermine the PGE and rhenium, and Os isotope ratios in a range of geochemical reference materials (TDB-1, WGB-1, BHVO-2 and UB-N). The obtained results agree well with those previously published. This new method enables PGE-Re abundances and Os isotopic ratios to be determined on the same sample digestion, and circumvents the problems created by sample heterogeneity when comparing PGE and Re-Os isotope data. | |
dc.publisher | Wiley-Blackwell Publishing | |
dc.subject | platinum-group elements | |
dc.subject | ICP-MS | |
dc.subject | N-benzoyl-N-phenylhydroxylamine extraction resin | |
dc.subject | N-TIMS | |
dc.subject | cation exchange resin | |
dc.subject | Re-Os isotopes | |
dc.title | Determination of Platinum-Group Elements and Re-Os Isotopes using ID-ICP-MS and N-TIMS from a Single Digestion after Two-Stage Column Separation | |
dc.type | Journal Article | |
dcterms.source.volume | 38 | |
dcterms.source.number | 1 | |
dcterms.source.startPage | 37 | |
dcterms.source.endPage | 50 | |
dcterms.source.issn | 1639-4488 | |
dcterms.source.title | Geostandards and Geoanalytical Research | |
curtin.note |
This is the accepted version of the following article: Li, J. and Jiang, X. and Xu, J. and Zhong, L. and Wang, X. and Wang, G. and Zhao, P. 2014. Determination of Platinum-Group Elements and Re-Os Isotopes using ID-ICP-MS and N-TIMS from a Single Digestion after Two-Stage Column Separation. Geostandards and Geoanalytical Research. 38 (1): pp. 37-50., which has been published in final form at | |
curtin.department | Department of Applied Geology | |
curtin.accessStatus | Open access |