Show simple item record

dc.contributor.authorRutter, C.
dc.contributor.authorKnudsen, A.
dc.contributor.authorMarsh, T.
dc.contributor.authorDoria-Rose, V.
dc.contributor.authorJohnson, E.
dc.contributor.authorPabiniak, C.
dc.contributor.authorKuntz, K.
dc.contributor.authorVan Ballegooijen, M.
dc.contributor.authorZauber, A.
dc.contributor.authorLansdorp_Vogelaar, Iris
dc.date.accessioned2017-03-15T22:16:52Z
dc.date.available2017-03-15T22:16:52Z
dc.date.created2017-02-26T19:31:41Z
dc.date.issued2015
dc.identifier.citationRutter, C. and Knudsen, A. and Marsh, T. and Doria-Rose, V. and Johnson, E. and Pabiniak, C. and Kuntz, K. et al. 2015. Validation of Models Used to Inform Colorectal Cancer Screening Guidelines. Medical Decision Making. 36 (5): pp. 604-614.
dc.identifier.urihttp://hdl.handle.net/20.500.11937/49961
dc.identifier.doi10.1177/0272989X15622642
dc.description.abstract

Background: Microsimulation models synthesize evidence about disease processes and interventions, providing a method for predicting long-Term benefits and harms of prevention, screening, and treatment strategies. Because models often require assumptions about unobservable processes, assessing a model's predictive accuracy is important. Methods: We validated 3 colorectal cancer (CRC) microsimulation models against outcomes from the United Kingdom Flexible Sigmoidoscopy Screening (UKFSS) Trial, a randomized controlled trial that examined the effectiveness of one-Time flexible sigmoidoscopy screening to reduce CRC mortality. The models incorporate different assumptions about the time from adenoma initiation to development of preclinical and symptomatic CRC. Analyses compare model predictions to study estimates across a range of outcomes to provide insight into the accuracy of model assumptions. Results: All 3 models accurately predicted the relative reduction in CRC mortality 10 years after screening (predicted hazard ratios, with 95% percentile intervals: 0.56 [0.44, 0.71], 0.63 [0.51, 0.75], 0.68 [0.53, 0.83]; estimated with 95% confidence interval: 0.56 [0.45, 0.69]). Two models with longer average preclinical duration accurately predicted the relative reduction in 10-year CRC incidence. Two models with longer mean sojourn time accurately predicted the number of screen-detected cancers. All 3 models predicted too many proximal adenomas among patients referred to colonoscopy. Conclusion: Model accuracy can only be established through external validation. Analyses such as these are therefore essential for any decision model. Results supported the assumptions that the average time from adenoma initiation to development of preclinical cancer is long (up to 25 years), and mean sojourn time is close to 4 years, suggesting the window for early detection and intervention by screening is relatively long. Variation in dwell time remains uncertain and could have important clinical and policy implications.

dc.publisherSage Publications, Inc.
dc.titleValidation of Models Used to Inform Colorectal Cancer Screening Guidelines
dc.typeJournal Article
dcterms.source.volume36
dcterms.source.number5
dcterms.source.startPage604
dcterms.source.endPage614
dcterms.source.issn0272-989X
dcterms.source.titleMedical Decision Making
curtin.accessStatusFulltext not available


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record