Small scale Direct Potable Reuse (DPR) project for a remote area
Access Status
Authors
Date
2017Type
Metadata
Show full item recordCitation
Source Title
DOI
ISSN
School
Collection
Abstract
An Advanced Water Treatment Plant (AWTP) for potable water recycling in Davis Station Antarctica was trialed using secondary effluent at Selfs Point in Hobart, Tasmania, for nine months. The trials demonstrated the reliability of performance of a seven barrier treatment process consisting of ozonation, ceramic microfiltration (MF), biologically activated carbon, reverse osmosis, ultra-violet disinfection, calcite contactor and chlorination. The seven treatment barriers were required to meet the high log removal values (LRV) required for pathogens in small systems during disease outbreak, and on-line verification of process performance was required for operation with infrequent operator attention. On-line verification of pathogen LRVs, a low turbidity filtrate of approximately 0.1 NTU (Nephelometric Turbidity Unit), no long-term fouling and no requirement for clean-in-place (CIP) was achieved with the ceramic MF. A pressure decay test was also reliably implemented on the reverse osmosis system to achieve a 2 LRV for protozoa, and this barrier required only 2-3 CIP treatments each year. The ozonation process achieved 2 LRV for bacteria and virus with no requirement for an ozone residual, provided the ozone dose was > 11.7 mg/L. Extensive screening using multi-residue gas chromatography-mass spectrometry (GC-MS) and liquid chromatography-mass spectrometry (LC-MS) database methods that can screen for more than 1200 chemicals found that few chemicals pass through the barriers to the final product and rejected (discharge) water streams. The AWTP plant required 1.93 kWh/m3 when operated in the mode required for Davis Station and was predicted to require 1.27 kWh/m3 if scaled up to 10 ML/day. The AWTP will be shipped to Davis Station for further trials before possible implementation for water recycling. The process may have application in other small remote communities.
Related items
Showing items related by title, author, creator and subject.
-
Nottle, Caroline E. (2013)As the international standards for drinking water become more stringent and the health guideline values for currently regulated disinfection by-products (DBPs) decrease, the challenge increases for water utilities to ...
-
Ataei, A.; Gharaie, M.; Parand, Reza; Panjeshahi, E. (2010)Re-circulating cooling water systems offer the means to remove heat from a wide variety of industrial processes that generate excess heat. Such systems consist of a cooling tower and a heat-exchanger network that ...
-
Allard, Sebastien; Nottle, C.; Chan, W.; Joll, Cynthia; Von Gunten, Urs (2013)The presence of iodinated disinfection by-products (I-DBPs) in drinking water poses a potential health concern since it has been shown that I-DBPs are generally more genotoxic and cytotoxic than their chlorinated and ...