Show simple item record

dc.contributor.authorHo, Daniel
dc.contributor.authorSquelch, Andrew
dc.contributor.authorSun, Zhonghua
dc.date.accessioned2017-03-17T08:30:03Z
dc.date.available2017-03-17T08:30:03Z
dc.date.created2017-02-19T19:31:44Z
dc.date.issued2017
dc.identifier.citationHo, D. and Squelch, A. and Sun, Z. 2017. Modelling of aortic aneurysm and aortic dissection through 3D printing. Journal of Medical Radiation Sciences. 64: pp. 10-17.
dc.identifier.urihttp://hdl.handle.net/20.500.11937/51226
dc.identifier.doi10.1002/jmrs.212
dc.description.abstract

Introduction: The aim of this study was to assess if the complex anatomy of aortic aneurysm and aortic dissection can be accurately reproduced from a contrast-enhanced computed tomography (CT) scan into a three-dimensional (3D) printed model. Methods: Contrast-enhanced cardiac CT scans from two patients were post-processed and produced as 3D printed thoracic aorta models of aortic aneurysm and aortic dissection. The transverse diameter was measured at five anatomical landmarks for both models, compared across three stages: the original contrast-enhanced CT images, the stereolithography (STL) format computerised model prepared for 3D printing and the contrast-enhanced CT of the 3D printed model. For the model with aortic dissection, measurements of the true and false lumen were taken and compared at two points on the descending aorta. Results: Three-dimensional printed models were generated with strong and flexible plastic material with successful replication of anatomical details of aortic structures and pathologies. The mean difference in transverse vessel diameter between the contrast-enhanced CT images before and after 3D printing was 1.0 and 1.2 mm, for the first and second models respectively (standard deviation: 1.0 mm and 0.9 mm). Additionally, for the second model, the mean luminal diameter difference between the 3D printed model and CT images was 0.5 mm. Conclusion: Encouraging results were achieved with regards to reproducing 3D models depicting aortic aneurysm and aortic dissection. Variances in vessel diameter measurement outside a standard deviation of 1 mm tolerance indicate further work is required into the assessment and accuracy of 3D model reproduction. © 2017 Australian Society of Medical Imaging and Radiation Therapy and New Zealand Institute of Medical Radiation Technology.

dc.publisherJohn Wiley & Sons
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.titleModelling of aortic aneurysm and aortic dissection through 3D printing
dc.typeJournal Article
dcterms.source.issn2051-3895
dcterms.source.titleJournal of Medical Radiation Sciences
curtin.departmentDepartment of Exploration Geophysics
curtin.accessStatusOpen access


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

http://creativecommons.org/licenses/by/4.0/
Except where otherwise noted, this item's license is described as http://creativecommons.org/licenses/by/4.0/