    Disconnection of single-phase rooftop PVs after short-circuit faults in residential feeders

    Access Status
    Fulltext not available
    Authors
    Hosseinian Yengejeh, H.
    Shahnia, Farhad
    Islam, Syed
    Date
    2016
    Type
    Journal Article
    
    Metadata
    Show full item record
    Citation
    Hosseinian Yengejeh, H. and Shahnia, F. and Islam, S. 2016. Disconnection of single-phase rooftop PVs after short-circuit faults in residential feeders. Australian Journal of Electrical and Electronics Engineering. 13 (2): pp. 151-165.
    Source Title
    Australian Journal of Electrical and Electronics Engineering
    DOI
    10.1080/1448837X.2016.1221637
    ISSN
    1448-837X
    School
    Department of Electrical and Computer Engineering
    URI
    http://hdl.handle.net/20.500.11937/5169
    Collection
    • Curtin Research Publications
    Abstract

    © 2016 Engineers Australia.This paper presents an analysis on the disconnection time of single-phase rooftop photovoltaic systems (PVs), located in a three-phase four-wire low voltage distribution feeder, after a single-phase and a three-phase short-circuit fault on the low-voltage feeder. The paper aims to evaluate and discuss the disconnection time and disconnection sequence of PVs in a network with 100% PV penetration level to evaluate the islanding issues that are related to the safety of people and the damage of electrical apparatus. The impact of different parameters such as the location of the fault, impedance of the fault and the ratio of PVs generation capacity to the load demand are contemplated in the analysis. Furthermore, the influence of the network earthing in the form of multiple earthed neutral and non-effectively grounded systems are evaluated on the PVs disconnection time. This research intends to figure out the conditions under which the PVs in the feeder may fail to disconnect after a single-phase or three-phase fault and continue to feed the fault.

    Related items

    Showing items related by title, author, creator and subject.

    • Disconnection time and sequence of rooftop PVs under short-circuit faults in low voltage networks
      Yengejeh, H.; Shahnia, F.; Islam, Syed (2015)
      This paper presents an analysis on the disconnection time of single-phase rooftop PVs, located in a three-phase four-wire low voltage distribution feeder after a line-to-ground short-circuit fault on the low voltage feeder. ...
    • Contributions of Single–Phase Rooftop PVs on Short Circuits Faults in Residential Feeders
      Yengejeh, H.; Shahnia, Farhad; Islam, Syed (2014)
      Sensitivity analysis results are presented to investigate the presence of single–phase rooftop Photovoltaic Cells (PV) in low voltage residential feeders, during short circuits in the overhead lines. The PV rating and ...
    • Impact of Distributed Rooftop Photovoltaic Systems on Short-Circuit Faults in the Supplying Low Voltage Networks
      Hosseinian Yengejeh, H.; Shahnia, F.; Islam, Syed (2017)
      © 2017, Copyright © Taylor & Francis Group, LLC. This article evaluates the effect of randomly distributed, residential single-phase rooftop photovoltaic systems in the low voltage residential networks, during ...
    Advanced search

    Browse

    Communities & CollectionsIssue DateAuthorTitleSubjectDocument TypeThis CollectionIssue DateAuthorTitleSubjectDocument Type

    My Account

    Admin

    Statistics

    Most Popular ItemsStatistics by CountryMost Popular Authors

    Follow Curtin

    • 
    • 
    • 
    • 
    • 

    CRICOS Provider Code: 00301JABN: 99 143 842 569TEQSA: PRV12158

    Copyright | Disclaimer | Privacy statement | Accessibility

    Curtin would like to pay respect to the Aboriginal and Torres Strait Islander members of our community by acknowledging the traditional owners of the land on which the Perth campus is located, the Whadjuk people of the Nyungar Nation; and on our Kalgoorlie campus, the Wongutha people of the North-Eastern Goldfields.