Curtin University Homepage
  • Library
  • Help
    • Admin

    espace - Curtin’s institutional repository

    JavaScript is disabled for your browser. Some features of this site may not work without it.
    View Item 
    • espace Home
    • espace
    • Curtin Research Publications
    • View Item
    • espace Home
    • espace
    • Curtin Research Publications
    • View Item

    Usage of spacers in respiratory laboratories and the delivered salbutamol dose of spacers available in Australia and New Zealand

    Access Status
    Fulltext not available
    Authors
    Hall, Graham
    Annese, T.
    Looi, K.
    Devadason, S.
    Date
    2011
    Type
    Journal Article
    
    Metadata
    Show full item record
    Citation
    Hall, G. and Annese, T. and Looi, K. and Devadason, S. 2011. Usage of spacers in respiratory laboratories and the delivered salbutamol dose of spacers available in Australia and New Zealand. Respirology. 16 (4): pp. 639-644.
    Source Title
    Respirology
    DOI
    10.1111/j.1440-1843.2011.01928.x
    ISSN
    1323-7799
    School
    School of Physiotherapy and Exercise Science
    URI
    http://hdl.handle.net/20.500.11937/54259
    Collection
    • Curtin Research Publications
    Abstract

    Background and objective: Purchase and disinfection costs together with medication delivery factors may influence the choice of drug delivery options. This study assessed salbutamol delivery habits used in respiratory laboratories and quantified the delivered salbutamol dose of locally available spacers. Methods: An online survey was used to obtain data on disinfection processes, costs and delivery device choices. The delivered dose of six commercial spacers was assessed. Particle size distribution of salbutamol (Ventolin, GSK, 100 µg/actuation) from six spacers of each type was measured by quantifying the amount of drug (µg) deposited on each stage of an Anderson Cascade Impactor (ACI) using UV spectrophotometry. Clinical conditions were simulated using a flow volume simulator (FVS) and delivery of salbutamol via a pressurized metered dose inhaler and spacer to a low-resistance filter was measured. Results: Fifty survey responses were obtained, with 37 (74%) using ≥1 type of spacer of which 92% processed single use spacers. The most commonly used spacers were Volumatic (n = 24), Breath-a-tech (n = 8) and Space Chamber (n = 7). The median disinfection cost was $2.45. Delivered salbutamol dose varied significantly and ranged from 16.98 to 38.28 µg with the ACI and 22.56 to 58.82 µg with the FVS. Using the FVS, small-volume spacers delivered similar doses (22.56 to 28.46 µg), while large-volume spacers delivery was more varied (24.31 to 58.82 µg). Conclusions: The majority of respiratory laboratories had not updated re-processing policies to comply with new regulations. The delivered salbutamol dose varied significantly and this might effect the choice of preferred spacer type.

    Related items

    Showing items related by title, author, creator and subject.

    • Bronchodilator responsiveness in children with asthma is not influenced by spacer device selection
      D'Vaz, N.; Okitika, T.; Shackleton, C.; Devadason, S.; Hall, Graham (2019)
      Introduction: Spacer devices optimize delivery of aerosol therapies and maximize therapeutic efficacy. We assessed the impact of spacer device on the prevalence and magnitude of bronchodilator response (BDR) in children ...
    • Validation of methodology for recording breathing and simulating drug delivery through spacers and valved holding chambers
      Schultz, A.; Le Souëf, T.; Looi, K.; Zhang, Guicheng; Le Souëf, P.; Devadason, S. (2010)
      Background: Output from spacers (or valved holding chambers) is sensitive to changes in breathing pattern. Different spacers have unique characteristics that may influence breathing. A method used for breathing simulation, ...
    • Incentive device improves spacer technique but not clinical outcome in preschool children with asthma
      Schultz, A.; Sly, P.; Zhang, Guicheng; Venter, A.; Le Souãf, P.; Devadason, S. (2012)
      Aim: To investigate the influence of an incentive device, the Funhaler, on spacer technique and symptom control in young children with asthma and recurrent wheeze. Methods: Randomised controlled trial where 132 2-6 year ...
    Advanced search

    Browse

    Communities & CollectionsIssue DateAuthorTitleSubjectDocument TypeThis CollectionIssue DateAuthorTitleSubjectDocument Type

    My Account

    Admin

    Statistics

    Most Popular ItemsStatistics by CountryMost Popular Authors

    Follow Curtin

    • 
    • 
    • 
    • 
    • 

    CRICOS Provider Code: 00301JABN: 99 143 842 569TEQSA: PRV12158

    Copyright | Disclaimer | Privacy statement | Accessibility

    Curtin would like to pay respect to the Aboriginal and Torres Strait Islander members of our community by acknowledging the traditional owners of the land on which the Perth campus is located, the Whadjuk people of the Nyungar Nation; and on our Kalgoorlie campus, the Wongutha people of the North-Eastern Goldfields.