dc.identifier.citationZhou, L. and Reen, F. and O'Gara, F. and McSweeney, C. and Clarke, S. and Glennon, J. and Luong, J. et al. 2012. Analysis of pseudomonas quinolone signal and other bacterial signalling molecules using capillaries coated with highly charged polyelectrolyte monolayers and boron doped diamond electrode. Journal of Chromatography A. 1251: pp. 169-175.
dc.identifier.urihttp://hdl.handle.net/20.500.11937/5530
dc.identifier.doi10.1016/j.chroma.2012.06.064
dc.description.abstract

Coated capillary electrophoresis equipped with a boron doped diamond (BDD) electrode was developed for analysis of chemically synthesised 2-heptyl-3-hydroxy-4-quinolone (HHQ), 2-heptyl-3-hydroxy-4-quinolone (PQS), and 2-methyl analogues. Detection was then extended to biological samples. PQS and its biological precursor, HHQ, are two key regulators of bacterial cooperative behaviour known as quorum sensing in the nosocomial pathogen Pseudomonas aeruginosa. The fused silica capillary was coated with a thin layer of poly (diallyldimethylammonium) chloride to reverse the electroosmosis, allowing fast migration of PQS and HHQ with improved selectivity. The four model compounds were baseline resolved using a 50 mM H3PO4–Tris, pH 2.0 buffer with 20% (v/v) acetonitrile as buffer additive. With an injection time of 3 s, the detection limits of four analytes ranging from 60 to 100 nM (S/N = 3) were observed when the BDD electrode was poised at +1.5 V vs. 3 M Ag/AgCl. As expected, no PQS or HHQ was detected from the supernatant of the P. aeruginosa (pqsA) mutant. A concentration of HHQ of 247 μM was detected from the supernatant of the pqsH mutant, which catalyses the conversion of HHQ to PQS in the presence of molecular oxygen by monooxygenase. The separation and detection scheme was applicable to follow the conversion of HHQ to PQS in P. aeruginosa when entering the stationary phase of growth. The results obtained by coated capillary electrophoresis with BDD detection were validated and compared well with LC–MS data.

dc.publisherElsevier BV
dc.titleAnalysis of pseudomonas quinolone signal and other bacterial signalling molecules using capillaries coated with highly charged polyelectrolyte monolayers and boron doped diamond electrode
dc.typeJournal Article
dcterms.source.volume1251
dcterms.source.startPage169
dcterms.source.endPage175
dcterms.source.issn0021-9673
dcterms.source.titleJournal of Chromatography A
curtin.accessStatusFulltext not available


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record