dc.description.abstract

This paper presents the ultrasonic velocity measurement method which investigates the possible effects of high voltage high frequency pulsed power on cortical bone material elasticity. Before applying a pulsed power signal on a live bone, it is essential to determine the safe parameters of pulsed power applied on bone non-destructively. Therefore, the possible changes in cortical bone material elasticity due to a specified pulsed power excitation have been investigated. A controllable positive buck-boost converter with adjustable output voltage and frequency has been used to generate high voltage pulses (500V magnitude at 10 KHz frequency). To determine bone elasticity, an ultrasonic velocity measurement has been conducted on two groups of control (unexposed to pulse power but in the same environmental condition) and cortical bone samples exposed to pulsed power. Young's modulus of cortical bone samples have been determined and compared before and after applying the pulsed power signal. After applying the high voltage pulses, no significant variation in elastic property of cortical bone specimens was found compared to the control. The result shows that pulsed power with nominated parameters can be applied on cortical bone tissue without any considerable negative effect on elasticity of bone material.

dc.titleEvaluation cortical bone elasticity in response to pulse power excitation using ultrasonic technique
dc.typeConference Paper
dcterms.source.startPage676
dcterms.source.endPage680
dcterms.source.titleProceedings of the 9th IASTED International Conference on Biomedical Engineering, BioMed 2012
dcterms.source.seriesProceedings of the 9th IASTED International Conference on Biomedical Engineering, BioMed 2012
dcterms.source.isbn9780889869097
curtin.departmentSchool of Electrical Engineering and Computing
curtin.accessStatusFulltext not available


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record