The South West Hub CCS project (SW Hub) in Western Australia is proceeding to reduce uncertainties related to injectivity, capacity and containment through a well drilling, coring and logging program. This study provides reviews of well designs for in situ tests and well-based monitoring methods at CO2 storage sites. Wells are expensive and complex engineering undertakings, and their design including size, geometry and materials, greatly impacts on the type of data that can be collected and techniques for monitoring that can be performed at a site. There is no ‘one size-fits-all’ monitoring well, but there is a tool-box or ensemble of solutions that can achieve a broad range of relevant monitoring objectives given constraints of site characteristics and budgetary limitations. For the SW Hub, a multi-well, multi-use and multi-completion monitoring scheme is proposed that combines the benefit of four different types of monitoring wells in addition to equipping the injector: 1) a well completed in the reservoir for conformance monitoring with additional completion above the storage complex, 2) a well completed above the confining layer for ensuring containment, 3) a well completed in the reservoir in the vicinity of an identified fault for monitoring potential across-fault migration and fault re-activation risks and 4) a well for fault leakage surveillance above the storage complex.
Related items
Showing items related by title, author, creator and subject.
-
Lisk, Mark (2012)A comprehensive examination of the hydrocarbon charge and formation water history of the central Vulcan Sub-basin, Timor Sea has been completed and a model developed to describe the evolution of the region’s petroleum ...
-
Application of online impulse technique to diagnose inter-turn short circuit in transformer windingsMohseni, B.; Hashemnia, N.; Islam, Syed; Zhao, Z. (2016)Inter-turn short circuit fault is a significant problem in power transformers which if not detected at early stages, can propagate in power networks and eventually burgeon into catastrophic faults and substantial costs. ...
-
Wang, Zhongwei (2010)Geared systems have been widely used in mechanical applications for more than a hundred years. A large range of literature has been published especially for spur/helical gear systems and the investigations into technical ...