Show simple item record

dc.contributor.authorYamada, A.
dc.contributor.authorLuis, S.
dc.contributor.authorSathianathan, D.
dc.contributor.authorKhandheria, B.
dc.contributor.authorCafaro, J.
dc.contributor.authorHamilton-Craig, C.
dc.contributor.authorPlatts, D.
dc.contributor.authorHaseler, Luke
dc.contributor.authorBurstow, D.
dc.contributor.authorChan, J.
dc.date.accessioned2018-01-30T08:02:11Z
dc.date.available2018-01-30T08:02:11Z
dc.date.created2018-01-30T05:59:14Z
dc.date.issued2014
dc.identifier.citationYamada, A. and Luis, S. and Sathianathan, D. and Khandheria, B. and Cafaro, J. and Hamilton-Craig, C. and Platts, D. et al. 2014. Reproducibility of regional and global longitudinal strains derived from two-dimensional speckle-tracking and Doppler tissue imaging between expert and novice readers during quantitative dobutamine stress echocardiography. Journal of the American Society of Echocardiography. 27 (8): pp. 880-887.
dc.identifier.urihttp://hdl.handle.net/20.500.11937/60772
dc.identifier.doi10.1016/j.echo.2014.04.016
dc.description.abstract

Background: Longitudinal strain (LS) is a quantitative parameter that adds incremental value to wall motion analysis. The aim of this study was to compare the reproducibility of LS derived from Doppler tissue imaging and speckle-tracking between an expert and a novice strain reader during dobutamine stress echocardiography (DSE). Methods: Forty-one patients (mean age, 65 ± 15 years; mean ejection fraction, 58 ± 11%) underwent DSE per clinical protocol. Global LS derived from speckle-tracking and regional LS derived from both speckle-tracking and Doppler tissue imaging were measured twice by an expert strain reader and also measured twice by a novice strain reader. Intraobserver and interobserver analyses were performed using intraclass correlation coefficients (ICC), Bland-Altman analysis, and absolute difference values (mean ± SD). Results: Global LS measured by the expert strain reader demonstrated high intraobserver measurement reproducibility (rest: ICC = 0.95, absolute difference = 5.5 ± 4.9%; low dose: ICC = 0.96, absolute difference = 5.7 ± 3.7%; peak dose: ICC = 0.87, absolute difference = 11.4 ± 8.4%). Global LS measured by the novice strain reader also demonstrated high intraobserver reproducibility (rest: ICC = 0.97, absolute difference = 4.1 ± 3.4%; low dose: ICC = 0.94, absolute difference = 5.4 ± 5.9%; peak dose: ICC = 0.94, absolute difference = 6.1 ± 4.8%). Global LS also showed high interobserver agreement between the expert and novice readers at all stages of DSE (rest: ICC = 0.90, absolute difference = 8.5 ± 7.5%; low dose: ICC = 0.90, absolute difference = 8.9 ± 7.1%; peak dose: ICC = 0.87, absolute difference = 10.8 ± 8.4%). Of all parameters studied, LS derived from Doppler tissue imaging had relatively low interobserver and intraobserver agreement. Conclusions: Global LS is highly reproducible during all stages of DSE. This variable is a potentially reliable and reproducible measure of myocardial deformation.

dc.titleReproducibility of regional and global longitudinal strains derived from two-dimensional speckle-tracking and Doppler tissue imaging between expert and novice readers during quantitative dobutamine stress echocardiography
dc.typeJournal Article
dcterms.source.volume27
dcterms.source.number8
dcterms.source.startPage880
dcterms.source.endPage887
dcterms.source.issn0894-7317
dcterms.source.titleJournal of the American Society of Echocardiography
curtin.departmentSchool of Physiotherapy and Exercise Science
curtin.accessStatusFulltext not available


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record