Show simple item record

dc.contributor.authorShinmoto Torres, R.
dc.contributor.authorVisvanathan, R.
dc.contributor.authorAbbott, D.
dc.contributor.authorHill, Keith
dc.contributor.authorRanasinghe, D.
dc.date.accessioned2018-02-06T06:14:36Z
dc.date.available2018-02-06T06:14:36Z
dc.date.created2018-02-06T05:49:46Z
dc.date.issued2017
dc.identifier.citationShinmoto Torres, R. and Visvanathan, R. and Abbott, D. and Hill, K. and Ranasinghe, D. 2017. A battery-less and wireless wearable sensor system for identifying bed and chair exits in a pilot trial in hospitalized older people. PLoS ONE. 12(10): e0185670.
dc.identifier.urihttp://hdl.handle.net/20.500.11937/62956
dc.identifier.doi10.1371/journal.pone.0185670
dc.description.abstract

© 2017 Shinmoto Torres et al. Falls in hospitals are common, therefore strategies to minimize the impact of these events in older patients and needs to be examined. In this pilot study, we investigate a movement monitoring sensor system for identifying bed and chair exits using a wireless wearable sensor worn by hospitalized older patients. We developed a movement monitoring sensor system that recognizes bed and chair exits. The system consists of a machine learning based activity classifier and a bed and chair exit recognition process based on an activity score function. Twenty-six patients, aged 71 to 93 years old, hospitalized in the Geriatric Evaluation and Management Unit participated in the supervised trials. They wore over their attire a battery-less, lightweight and wireless sensor and performed scripted activities such as getting off the bed and chair. We investigated the system performance in recognizing bed and chair exits in hospital rooms where RFID antennas and readers were in place. The system’s acceptability was measured using two surveys with 0–10 likert scales. The first survey measured the change in user perception of the system before and after a trial; the second survey, conducted only at the end of each trial, measured user acceptance of the system based on a multifactor sensor acceptance model. The performance of the system indicated an overall recall of 81.4%, precision of 66.8% and F-score of 72.4% for joint bed and chair exit recognition. Patients demonstrated improved perception of the system after use with overall score change from 7.8 to 9.0 and high acceptance of the system with score 6.7 for all acceptance factors. The present pilot study suggests the use of wireless wearable sensors is feasible for detecting bed and chair exits in a hospital environment.

dc.publisherPublic Library of Science
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.titleA battery-less and wireless wearable sensor system for identifying bed and chair exits in a pilot trial in hospitalized older people
dc.typeJournal Article
dcterms.source.volume12
dcterms.source.number10
dcterms.source.issn1932-6203
dcterms.source.titlePLoS ONE
curtin.departmentSchool of Physiotherapy and Exercise Science
curtin.accessStatusOpen access


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

http://creativecommons.org/licenses/by/4.0/
Except where otherwise noted, this item's license is described as http://creativecommons.org/licenses/by/4.0/