Testing of generic volatile inhibitor compounds in different top-of-the-line corrosion laboratory test methods
dc.contributor.author | Oehler, Mike | |
dc.contributor.author | Bailey, Stuart | |
dc.contributor.author | Gubner, Rolf | |
dc.contributor.author | Gough, M. | |
dc.contributor.editor | Nace International | |
dc.date.accessioned | 2017-01-30T10:57:12Z | |
dc.date.available | 2017-01-30T10:57:12Z | |
dc.date.created | 2013-03-07T20:00:35Z | |
dc.date.issued | 2012 | |
dc.identifier.citation | Oehler, M.C. and Bailey, S.I. and Gubner, R. and Gough, M. 2012. Testing of generic volatile inhibitor compounds in different top-of-the-line corrosion laboratory test methods, in Nace International (ed), Corrosion 2012, Mar 11-15 2012. Salt Lake City: Nace International. | |
dc.identifier.uri | http://hdl.handle.net/20.500.11937/7037 | |
dc.description.abstract |
Top-of-the-Line (TOL) corrosion is a significant problem associated with the transportation of wet natural gas in the oil and gas industry. It has the potential to cost the industry millions of dollars every year through the replacement of affected pipelines and lost or deferred production. There is increasing research attention given to the development of continuous chemical treatment inhibitors to mitigate TOL corrosion. Different techniques have been developed; however, volatile corrosion inhibitors (VCIs) hold the most promise. It is anticipated that VCIs may be injected continuously into the produced fluids at the bottom of the line and due to their volatility disperse through the gas phase and ultimately co-condense along with water, organic acids and corrosive gases on the internal pipe wall, thus providing corrosion inhibition. Three generic volatile inhibitor compounds, a primary, a secondary and a tertiary amine have been tested in two different TOL and one bottom of the line (BOL) laboratory corrosion test; a Cooled Finger Probe and a Horizontal Cooled Tube to verify Top-of-the-Line inhibition properties and linear polarization resistance (LPR) measurements using a rotating cylinder electrode (RCE) setup to test their BOL inhibition properties. | |
dc.publisher | Nace International | |
dc.relation.uri | https://www.onepetro.org/conference-paper/NACE-2012-1483 | |
dc.subject | Top-of-the-line corrosion | |
dc.subject | Volatile corrosion inhibitor | |
dc.subject | Acetic acid | |
dc.title | Testing of generic volatile inhibitor compounds in different top-of-the-line corrosion laboratory test methods | |
dc.type | Conference Paper | |
dcterms.source.title | NACE Corrosion 2012 | |
dcterms.source.series | NACE Corrosion 2012 | |
dcterms.source.isbn | 978-162276078-7 | |
dcterms.source.conference | NACE Corrosion 2012 | |
dcterms.source.conference-start-date | Mar 11 2012 | |
dcterms.source.conferencelocation | Salt Lake City | |
dcterms.source.place | Online | |
curtin.department | ||
curtin.accessStatus | Fulltext not available |