Effect of thickness on the behaviour of axially loaded back-to-back cold-formed steel built-up channel sections - Experimental and numerical investigation
Access Status
Authors
Date
2018Type
Metadata
Show full item recordCitation
Source Title
ISSN
School
Collection
Abstract
© 2018 Institution of Structural Engineers In cold-formed steel structures, such as trusses, wall frames and portal frames, the use of back-to-back built-up cold-formed steel channel sections are becoming increasingly popular. In such an arrangement, intermediate fasteners are required at discrete points along the length, preventing the channel-sections from buckling independently. Current guidance in the AISI &AS/NZS for such back-to-back built-up cold-formed steel channel sections requires the use of modified slenderness in order to take into account the spacing of the fasteners. Limited research has been done on back-to-back built-up cold-formed steel columns to understand the effect of column thickness and slenderness's on axial capacity. This issue is addressed herein. This paper presents the results of 60 experimental tests performed on back-to-back built-up cold-formed steel channel sections under compression. Detailed observations on different failure modes and column strengths were made through varying thickness, length and cross section of columns. A non-linear finite element model was developed which includes material non-linearity, geometric imperfections and explicit modelling of web fasteners. The finite element model was validated against experimental results. A comprehensive parametric study consisting of 204 models has been carried out covering a wide range of thickness and slenderness for the considered back-to-back built-up columns. Axial capacities obtained from the numerical study were used to assess the performance of the current AISI& AS/NZS standards when applied to cold-formed back-to-back built up columns; obtained comparisons showed that AISI& AS/NZS standards are un-conservative for stub and short columns which were failed by local buckling whereas standards were over-conservative for the strength of intermediate and slender columns which were failed mainly by overall member buckling. This paper has therefore proposed improved design rules and verified their accuracy using finite element analysis and test results of back-to-back built-up cold-formed channel sections, subjected to axial compression.
Related items
Showing items related by title, author, creator and subject.
-
Roy, K.; Ting, T.; Lau, Hieng Ho; Lim, J. (2018)Copyright © 2018 Techno-Press, Ltd. Back-to-back built-up cold-formed steel un-lipped channel sections are used in cold-formed steel structures; such as trusses, wall frames and portal frames. In such built-up columns, ...
-
Lau, Hieng Ho; Ting, Chui Huon; Tang, Fu Ee; Mei, C. (2010)Researchers have noticed the advantages of utilizing built-up sections in steel structures. Several studies have shown that the performance of a structure is improved using built-up sections. Current industry design has ...
-
Ting, T.; Roy, K.; Lau, Hieng Ho; Lim, J. (2018)In cold-formed steel structures, such as trusses, wall frames, and portal frames, the use of back-to-back built-up cold-formed steel channel sections for the column members is becoming increasingly popular. In such an ...